EMOrbitEmergency medicine, in one orbit Open in the app

Central Venous Catheter Insertion and Care in the Emergency Department

EMORBIT-CP-36 · Chapter 1 · Resuscitation and Critical Care

Open in the appFree, works on your phone and offline, with every tool alongside.

One-page algorithm: Central Venous Catheter Insertion and Care in the Emergency Department
Attachment 1 · one-page algorithm

Evidence base: NICE; INS; epic3; RCEM

1Purpose

  1. 1.1 Standardize the decision to insert, the safe insertion, the confirmation, the care and the removal of central venous catheters (CVC) in the Emergency Department (ED), for adults, children and young people.

  2. 1.2 Establish, as the starting position of this guideline, that a central venous catheter is needed less often in the Emergency Department than is generally assumed. A large peripheral cannula, an ultrasound-guided cannula in a deep arm vein, an intraosseous needle and a vasopressor run peripherally between them cover the great majority of emergencies. The decision to insert a central line shall be justified and recorded, not reflexive.

  3. 1.3 State unambiguously, and consistently with EMORBIT-CP-11 (Sepsis and Septic Shock) and EMORBIT-CP-30 (Undifferentiated Shock), that a central venous catheter is not a prerequisite for starting or for continuing a vasopressor. Noradrenaline is started through a large proximal peripheral vein where the mean arterial pressure remains below 65 mmHg, and the absence of a central line shall never be the reason a hypotensive patient is left untreated.

  4. 1.4 Define the genuine indications for central venous access in the ED, the absolute and relative contraindications, and the conditions that change the choice of site rather than cancel the procedure.

  5. 1.5 Establish real-time ultrasound guidance as the standard for every central venous catheter insertion, and establish confirmation of the guidewire within the vein before the dilator is passed as the single step that prevents the catastrophic complication of arterial dilation.

  6. 1.6 Establish a full aseptic insertion bundle with maximal sterile barrier precautions, correct skin antisepsis including the drying time that is routinely ignored, a read-aloud checklist, and a nurse explicitly empowered to stop the procedure when an element is omitted.

  7. 1.7 Define correct catheter tip position, the confirmatory imaging required, and the management of a malposition.

  8. 1.8 Define the recognition and immediate management of every important complication, including the rule that a catheter which has been dilated into an artery shall not be removed in the Emergency Department.

  9. 1.9 Define the care of the line while the patient remains in the ED, and establish that a line placed in an emergency without full asepsis shall be documented as such and shall be replaced within 48 hours.

  10. 1.10 Define the insertion record, the documentation standard, the paediatric arrangements and who inserts in children, and the indications and technique for removal.

  11. 1.11 Ensure alignment with epic3 and current national infection prevention guidance on intravascular catheters, the National Institute for Health and Care Excellence (NICE) guidance on ultrasound locating devices, the Infusion Nurses Society Infusion Therapy Standards of Practice, the vascular access guidance of the Society of Critical Care Medicine (SCCM) and the European Society of Intensive Care Medicine (ESICM), the American Society of Anesthesiologists (ASA) practice guidelines for central venous access, and the central line bundle literature.

2Who this protocol applies to

  1. 2.1 Any patient of any age in the ED for whom central venous access is being considered, requested or performed.

  2. 2.2 Any patient who arrives in the ED with a central venous catheter already in place, for the purposes of the care, assessment, use and removal standards in this guideline.

  3. 2.3 Any patient in whom a decision has been taken not to insert a central venous catheter and to use peripheral or intraosseous access instead; the documentation standard in section 4.3.10 applies equally to that decision.

  4. 2.4 Patients requiring emergency renal replacement access, transvenous cardiac pacing or large-bore central access for massive transfusion, in respect of the vascular access component of those procedures.

  5. 2.5 Children and young people are included, with the paediatric arrangements in section 4.1.6 and Table 5. Children present to this department, receive intraosseous and central access, and require a stated standard for who inserts and by which route; this guideline therefore includes them. Central venous catheters in children are inserted by a named group of clinicians, agreed with paediatrics and anaesthesia, including out of hours.

3Not covered by this protocol

  1. 3.1 Peripheral intravenous cannulation, ultrasound-guided peripheral cannulation and midline catheters as procedures in their own right, which are covered by the local vascular access and infusion therapy standards; they appear here only as the alternatives that must be considered before a central line.

  2. 3.2 Arterial cannulation and arterial line insertion, which are a separate procedure with a separate standard.

  3. 3.3 Peripherally inserted central catheters (PICC) and tunnelled or implanted long-term devices, which are inserted by the vascular access or interventional radiology service outside the ED.

  4. 3.4 Umbilical venous catheterisation in the neonate, which is a neonatal procedure governed by the neonatal service.

  5. 3.5 The ongoing inpatient management of a central venous catheter after the patient has left the ED, the diagnosis and treatment of established catheter-related bloodstream infection beyond the first ED actions, and the management of catheter-related thrombosis beyond recognition and referral.

  6. 3.6 Extracorporeal membrane oxygenation and haemodialysis cannulation performed by the specialist service, other than the ED role in obtaining access the accepting team has specified.

  7. 3.7 The selection and escalation of vasopressors and inotropes, which is governed by EMORBIT-CP-11 and EMORBIT-CP-30; this guideline addresses only the vascular access through which they run.

4Protocol

  1. 4.1History and Assessment:

    1. 4.1.1Recognition — the Question Before the Procedure:

      1. 4.1.1.1 The first question is not "which site?" but "does this patient need a central line at all, now, in this department?" In most ED resuscitations the honest answer is no.

      2. 4.1.1.2 Three alternatives cover the great majority of emergencies (Table 1): two large-bore peripheral cannulae, which deliver volume faster than any multi-lumen central catheter; an ultrasound-guided cannula in a deep upper-arm vein, which resolves most "difficult access"; and an intraosseous needle, which reaches the central circulation in under a minute and takes every resuscitation drug including vasopressors.

      3. 4.1.1.3 A vasopressor is not a reason to insert a central line before it is started. Noradrenaline 4 mg in 250 mL (16 micrograms/mL) is started through a cannula of 20 gauge or larger in a large proximal vein, titrated from 0.05 micrograms/kg/minute to a mean arterial pressure of 65 mmHg or above, with the site inspected at least every 30 minutes (EMORBIT-CP-11 Attachment 4; EMORBIT-CP-30).

      4. 4.1.1.4 The line is therefore usually planned rather than performed immediately: the indication is identified, the vasopressor or treatment is already running peripherally, and the insertion happens when the operator, the equipment and the conditions are right — in the ED, or in the intensive care unit after transfer.

      5. 4.1.1.5 The reflex central line causes harm in three ways: it delays the treatment the patient actually needs; it exposes the patient to pneumothorax, arterial injury, thrombosis and bloodstream infection for no benefit; and it is frequently performed under conditions in which full asepsis is impossible, creating a line that must then be replaced.

      6. 4.1.1.6 Ask and record, before proceeding: what will this catheter deliver or measure that peripheral and intraosseous access cannot? What decision will change because of it? Why now, rather than after transfer?

      7. 4.1.1.7

        Table 1: What a central venous catheter is for, and what already does the job better — the honest starting position
        AccessTime to establishWhat it deliversWhere it is the right answer, and its limits
        Large-bore peripheral cannula (14G or 16G)Seconds to a few minutesThe highest flow rate of any access in the department: approximately 180–270 mL/minute by gravity for a short 16G to 14G cannulaThe resuscitation line. Two of these, sited in large proximal veins, out-perform any multi-lumen central catheter for volume. Blood, crystalloid, almost every emergency drug, and a bridging vasopressor all run through them
        Ultrasound-guided peripheral cannula in a deep upper-arm vein (basilic, brachial, cephalic)2–10 minutes in trained handsA 20G to 16G cannula, 45–65 mm long, in a vein that cannot be seen or feltThe answer to most "difficult access" that is otherwise escalated to a central line. It requires a long cannula, because a short one placed in a deep vein will fall out of it. Not for a vesicant or for a concentrated vasopressor preparation
        Intraosseous needle (proximal humerus preferred, then proximal tibia)Under 60 secondsApproximately 80–150 mL/minute at the humerus under a pressure bag; every resuscitation drug, including vasopressors, blood and contrastThe emergency answer when peripheral access fails. Reaches the central circulation within seconds. Painful in the conscious patient — give 2% preservative-free lidocaine through the needle first. A bridge, not a destination: replace within 24 hours
        Midline catheter10–20 minutesA 8–20 cm catheter with its tip in the axillary vein, below the axillaA ward and observation-unit device for several days of non-irritant therapy. It is not a central line, does not take a vasopressor or vesicant, and has no place in the initial resuscitation
        Peripherally inserted central catheter (PICC)30–60 minutes, usually a vascular access serviceTrue central tip position through an arm veinFor planned medium-term therapy after the ED phase. Higher thrombosis rate than a short-term central catheter; slow to place; not an emergency device
        Central venous catheter (multi-lumen, 7 Fr, 16–20 cm)10–25 minutes including preparation, asepsis and confirmationApproximately 50–60 mL/minute through the widest (distal) lumen — slower than a 16G peripheral cannula, because the lumen is long and narrowConcentrated and vesicant infusions, multiple incompatible infusions, central pressure and saturation measurement, and reliable long-stay access. It is a poor resuscitation line for volume. If volume is the problem, the answer is a short wide cannula or an introducer sheath, not a triple lumen
        Large-bore central introducer or dialysis catheter (8.5 Fr or larger)10–25 minutesApproximately 200–250 mL/minute or more; permits rapid transfusion and renal replacementMassive transfusion (EMORBIT-CP-27), renal replacement therapy and transvenous pacing. This — not a triple lumen — is the central catheter to choose when flow is the reason for the line

        Approximate flow figures are laboratory and manufacturer values for gravity flow and are given to make one point only: a multi-lumen central venous catheter is chosen for what can be infused through it and for what can be measured from it, and almost never for speed of volume replacement. All figures shall be verified locally against the devices actually stocked before use.

    2. 4.1.2Indications:

      1. 4.1.2.1 The indications for central venous access in the ED are set out in Table 2. Each requires the operator to be able to state what the line will do that other access cannot.

      2. 4.1.2.2 Vasopressor or inotrope requirement extending beyond the peripheral bridging period — the commonest genuine indication. The peripheral infusion is started first and is never delayed for the line.

      3. 4.1.2.3 A drug that cannot be given peripherally — a concentrated vasopressor preparation, concentrated potassium, hypertonic sodium chloride beyond an emergency bolus, calcium chloride by infusion, parenteral nutrition, or another agent the clinical pharmacist identifies as central-administration-only.

      4. 4.1.2.4 Central venous pressure or central venous oxygen saturation measurement, where it will change management. This is a narrow indication. A central venous pressure shall not be used to guide fluid therapy (EMORBIT-CP-30).

      5. 4.1.2.5 Renal replacement therapy access — requiring a dedicated large-bore dialysis catheter, not a standard multi-lumen catheter.

      6. 4.1.2.6 Transvenous cardiac pacing — requiring a sheath introducer.

      7. 4.1.2.7 Genuine failure of peripheral and intraosseous access, which means an ultrasound-guided peripheral attempt by a competent operator has failed or is impossible and intraosseous access has been placed, is contraindicated, or has failed.

      8. 4.1.2.8

        Table 2: Indications — and the common reasons for inserting a central line that are not indications
        IndicationWhat has to be true for it to applyNotes and cross-references
        GENUINE INDICATIONS IN THE EMERGENCY DEPARTMENT
        Vasopressor or inotrope requirement extending beyond the peripheral bridging periodA vasopressor is running, is expected to continue, and either the bridging period is coming to an end or the dose or duration exceeds what peripheral administration should carry. The infusion is started peripherally first and is never delayed for the line (EMORBIT-CP-11, EMORBIT-CP-30)Noradrenaline 4 mg in 250 mL (16 micrograms/mL) is the peripheral bridging preparation. The 4 mg in 50 mL (80 micrograms/mL) preparation shall be given centrally only. The need for a central line is a reason to plan one, not a reason to leave a patient hypotensive
        Drugs that cannot be given peripherallyA drug is required whose concentration, pH, osmolarity or vesicant properties make peripheral administration unsafe: concentrated vasopressor preparations, concentrated potassium, hypertonic sodium chloride beyond an emergency bolus, calcium chloride by infusion, parenteral nutrition, some chemotherapy and some antiarrhythmicsConfirm with the ED clinical pharmacist which preparations on the local formulary carry a central-administration-only requirement, and which of those have a peripherally administrable alternative for the ED phase
        Central venous pressure or central venous oxygen saturation measurement, where it will change managementThe clinician can state in advance what decision the number will change. A central venous pressure shall not be used to guide fluid therapy (EMORBIT-CP-30): a single value does not predict fluid responsiveness at any thresholdIn practice this is a narrow indication in the ED. A trend in central venous oxygen saturation, or a pressure measured for a specific question agreed with intensive care, may qualify; "we should know the CVP" does not
        Renal replacement therapy accessEmergency dialysis or haemofiltration is required in the ED or immediately afterwards — refractory hyperkalaemia (EMORBIT-CP-10), refractory acidosis, refractory fluid overload, or a dialysable poisoning (EMORBIT-CP-21)A dedicated large-bore dialysis catheter is required; a standard multi-lumen catheter will not support renal replacement. Preserve the subclavian and, where possible, the non-dominant arm circulation in any patient who may need long-term dialysis access
        Transvenous cardiac pacingHaemodynamically significant bradycardia or high-grade block unresponsive to atropine and to transcutaneous pacing, or where transcutaneous pacing cannot be toleratedRequires a sheath introducer. The right internal jugular vein gives the most direct route to the right ventricle and is the preferred site for pacing wire insertion; the left subclavian is the alternative
        Genuine failure of peripheral and intraosseous accessUltrasound-guided peripheral access has been attempted by a competent operator and has failed or is not possible, and intraosseous access has been placed or is contraindicated or has failed, and the patient still needs vascular access"Difficult access" recorded without an ultrasound-guided attempt is not failure of peripheral access. Intraosseous access is faster than a central line and shall not be skipped in favour of one in an emergency
        Extracorporeal or interventional requirementTherapeutic plasma exchange, extracorporeal support, or a planned interventional procedure requiring central venous accessThese are specialty decisions; the ED role is to obtain the access the accepting team specifies, at the site they specify
        THESE ARE NOT, BY THEMSELVES, INDICATIONS
        Starting a vasopressorNot an indication. A vasopressor is started through a large proximal peripheral cannula and titrated to a mean arterial pressure of 65 mmHg or above without waiting for central accessEMORBIT-CP-11 and EMORBIT-CP-30. The absence of a central line shall never be the reason a hypotensive patient is left untreated.
        Rapid volume resuscitationNot an indication. A short wide peripheral cannula or an intraosseous needle delivers volume faster than a multi-lumen central catheterWhere central large-bore access is genuinely needed for massive transfusion, the device is an introducer sheath, under EMORBIT-CP-27
        Intubation, sedation or mechanical ventilationNot an indication in itself. The decision follows the drugs and the monitoring actually required, not the presence of a tracheal tubeReconciled — see section 4.3.2
        "The patient is sick" or "the patient is going to intensive care"Not an indication. The receiving unit may insert the line under controlled conditions; an ED insertion that delays transfer or definitive treatment causes net harmWhere the line is deferred, the plan, the responsible team and the expected timeframe shall be documented before the patient leaves the department
        Blood sampling convenienceNot an indicationSampling is not a reason to accept a pneumothorax, an arterial injury or a bloodstream infection

        The indication shall be stated in the record in the operator’s own words before the procedure begins, together with why peripheral and intraosseous access will not serve. This single sentence is the most important entry in the insertion record, and it is the first performance indicator in section 11.

    3. 4.1.3Contraindications and What Changes the Site:

      1. 4.1.3.1 There are few absolute contraindications to central venous access, and most of them are contraindications to a site rather than to the procedure. Infection at the puncture site and thrombosis of the target vein prohibit that site; they do not prohibit a central line.

      2. 4.1.3.2 Infection at the insertion site and thrombosis of the target vein are absolute contraindications to that site or that vein, not absolute contraindications to central line insertion overall; a different site shall be used.

      3. 4.1.3.3 Coagulopathy and thrombocytopenia are relative. They change the site — to a compressible one, internal jugular or femoral, never the subclavian — the operator, and the catheter size. They do not prohibit a time-critical line.

      4. 4.1.3.4 A contralateral pneumothorax, chest drain or pneumonectomy is one of the most important relative contraindications in the department. A second pneumothorax on the remaining functioning side may be fatal. Either use the same side as the existing pathology, or use the femoral route, which carries no pneumothorax risk.

      5. 4.1.3.5 Local infection, burn or cellulitis at the proposed site prohibits that site.

      6. 4.1.3.6 Known thrombosis of the target vein prohibits that vein. Scan the vein before draping: an incompressible, echogenic or non-distensible vein is thrombosed.

      7. 4.1.3.7 Anticipated need for long-term dialysis access preserves the subclavian veins. Subclavian stenosis destroys the arteriovenous access of the ipsilateral arm, and a patient with stage 4 or 5 chronic kidney disease will need that arm. The arm veins of the planned fistula side shall also be protected from routine peripheral cannulation.

      8. 4.1.3.8

        Table 3: Contraindications, and the conditions that change the site rather than cancel the procedure
        ConditionEffect on the decisionWhat to do
        ABSOLUTE — for that site, not for central access as a whole
        Infection, cellulitis or burn at the proposed puncture siteAbsolute contraindication to that siteChoose another site. This does not mean the patient cannot have a central line
        Known thrombosis or occlusion of the target veinAbsolute contraindication to that veinChoose another vein. Scan the vein before you prepare the field: an incompressible, echogenic or non-distensible vein on ultrasound is a thrombosed vein, and this finding is one of the most valuable things pre-procedure ultrasound gives you
        Patient refusal in a patient with capacityAbsoluteDocument the discussion, the alternatives offered and the decision
        Vascular injury or disruption proximal to the site (for example superior vena cava obstruction, a traumatised or ligated vessel, a prior vascular procedure)Absolute for that territoryUse a site that drains into an intact vein. In suspected superior vena cava obstruction or upper-torso venous injury, use the femoral route
        RELATIVE — they change the site, the operator, or the timing
        Coagulopathy (INR above 1.5, prolonged activated partial thromboplastin time, therapeutic anticoagulation, liver failure, disseminated intravascular coagulation)Relative. It increases bleeding risk and makes an inadvertent arterial puncture much more dangerous. It does not prohibit insertion in a patient who needs oneUse a compressible site — internal jugular or femoral, never the subclavian, which cannot be compressed. Use ultrasound. Use the most experienced available operator. Correct the coagulopathy where time permits and the correction is itself indicated (EMORBIT-CP-25). Consider a smaller catheter
        ThrombocytopeniaRelative. A platelet count above 50 × 10⁹/L is the conventional target for a planned insertion; the evidence supports safe ultrasound-guided insertion at substantially lower counts, and an emergency insertion is not deferred for a platelet countCompressible site, ultrasound, experienced operator, smallest adequate catheter. Where platelets are transfused, this follows the local transfusion policy and shall not delay a genuinely time-critical line
        Contralateral pneumothorax, contralateral pneumonectomy, or severe unilateral lung diseaseRelative, and one of the most important in the department: a pneumothorax on the remaining good side can be fatalNever puncture the side opposite to an existing pneumothorax, chest drain or pneumonectomy. Either use the same side as the existing pathology (a second pneumothorax on a side already drained is survivable), or use the femoral route, which carries no pneumothorax risk at all
        Severe respiratory distress, inability to lie flat, agitation or an uncooperative patientRelative, and frequently decisiveTreat the distress first. Consider the femoral route, which does not require head-down positioning. Consider whether the line is needed at all at this moment, or whether sedation and airway control should come first
        Anticipated need for long-term haemodialysis access (chronic kidney disease stage 4 or 5, existing or planned fistula or graft)Relative but strongly directivePreserve the subclavian veins — subclavian stenosis destroys the arteriovenous access of the ipsilateral arm. Avoid the arm veins of the planned fistula side for peripheral access as well. Discuss with nephrology where an urgent dialysis catheter is required
        Anatomical distortion: neck or chest trauma, burns, previous surgery or radiotherapy, a large goitre, morbid obesity, a short neckRelativeUltrasound is mandatory, not optional. A different site is often easier than a heroic attempt at a distorted one
        Existing intracardiac device leads, or a permanent pacemaker on that sideRelativeAvoid the ipsilateral subclavian; ultrasound-guided internal jugular or femoral is preferred
        Raised intracranial pressureRelative, for the internal jugular route and for head-down positioningInternal jugular cannulation and Trendelenburg both raise intracranial pressure. The femoral route avoids both
        Cardiac arrest or a peri-arrest patientRelative to the site, not to the procedureDo not interrupt chest compressions to insert a line. Use the femoral route, which is away from the airway and the chest and can be performed during compressions; or use intraosseous access, which is faster (EMORBIT-CP-03)

        Correcting a coagulopathy, obtaining a platelet count, or waiting for a calmer moment are all reasonable where the line is not time-critical. Where the line is time-critical, the correct response to a relative contraindication is to change the site, use ultrasound and ask a more experienced operator — not to abandon the patient and not to proceed blind.

    4. 4.1.4Site Selection:

      1. 4.1.4.1 Right internal jugular vein — the default site for a planned insertion in a patient who can lie flat: superficial, large, excellent ultrasound visibility, compressible, and a straight course to the superior vena cava.

      2. 4.1.4.2 Subclavian / infraclavicular axillary vein — the lowest infection and the lowest symptomatic thrombosis rate, and the most comfortable line to keep clean. It carries the highest pneumothorax risk, cannot be compressed if the artery is punctured, and shall be avoided in coagulopathy and preserved in anticipated dialysis. Where it is used, the ultrasound-guided infraclavicular axillary approach is preferred to the landmark subclavian approach.

      3. 4.1.4.3 Femoral vein — the lowest mechanical risk, no pneumothorax risk, readily compressible, away from the airway and the chest, and performable during ongoing chest compressions. Femoral access is an entirely acceptable and often correct choice in a resuscitation, in cardiac arrest, in coagulopathy, in respiratory distress and where the neck and chest are occupied.

      4. 4.1.4.4 A femoral line placed to save time in a resuscitation is a correct decision, not a compromise. It can be changed later — re-sited electively once the patient is stable and the conditions permit full asepsis — and the reason for the femoral choice is documented at the time.

      5. 4.1.4.5 The evidence on site and infection is narrower than the traditional teaching: 3SITES (2015) found no significant difference between the femoral and jugular sites for the combined infection and thrombosis endpoint when the insertion bundle was followed. The asepsis of the insertion and the care of the line matter more than the anatomical site.

      6. 4.1.4.6 The right internal jugular and femoral veins are named routes, with the right internal jugular preferred and femoral use avoided beyond 72 hours where possible. The subclavian and infraclavicular axillary route is also included, because it is the site of choice for a line that will stay in for days, because it is the site that must be actively preserved in a dialysis candidate, and because the ED needs a stated position on a route its patients will receive upstream. The 72-hour femoral rule is a prompt to review rather than an automatic removal trigger, since the 3SITES data do not support routine re-siting on a timer.

      7. 4.1.4.7

        Table 4: Site selection — the trade-offs, stated plainly
        FactorRight internal jugular veinSubclavian / infraclavicular axillary veinFemoral vein
        Default role in the EDThe default site for a planned ED insertion in a cooperative patient who can lie flatThe site with the lowest infection and the lowest symptomatic thrombosis rate, but the highest pneumothorax rate and the one site that cannot be compressedEntirely acceptable in a resuscitation, in cardiac arrest, in coagulopathy, in respiratory distress, and where the chest or neck is unavailable
        Catheter-related bloodstream infectionIntermediateLowestHistorically described as the highest. 3SITES (2015) found no significant difference between femoral and jugular for the combined infection and thrombosis endpoint when the insertion bundle was followed. The site matters far less than the asepsis
        Symptomatic deep vein thrombosisIntermediateLowestHighest. Relevant to a line that will stay in for days, much less relevant to one that will be removed or re-sited within 24 to 48 hours
        Mechanical complicationLow with ultrasound. Carotid puncture is the main hazard; the dome of the pleura is close at the base of the neckHighest pneumothorax rate. The pleura lies immediately beneath the puncture. Haemothorax and subclavian artery puncture are the other hazardsLowest mechanical risk. No pneumothorax risk. Femoral artery puncture and retroperitoneal haematoma with a high puncture are the hazards
        Compressibility if the artery is puncturedCompressible against the transverse processes and the tracheaNOT COMPRESSIBLE. An arterial injury here bleeds into the chest and cannot be pressed. This is why the subclavian is the wrong site in coagulopathyReadily compressible against the femoral head, provided the puncture is below the inguinal ligament
        Ultrasound guidanceExcellent — the vein is superficial, large and easily seen in both short and long axis. The reference site for teachingAchievable at the infraclavicular axillary vein, which is the ultrasound-visible continuation of the subclavian; the subclavian proper is obscured by the clavicle. Requires more skillExcellent — superficial, large, easily seen
        Position requiredSupine, 10–15° Trendelenburg to distend the vein and reduce air embolism risk; head turned slightly away, not fully rotatedSupine, 10–15° Trendelenburg, arm at the side, a small roll between the scapulae if neededSupine, leg slightly abducted and externally rotated; reverse Trendelenburg (head up) distends the vein. The patient does not have to lie head-down, which is often decisive
        Access during resuscitationCompetes with the airway operator for the head endCompetes with chest compressions and defibrillation padsAway from the airway and the chest — it can be done during ongoing CPR
        Tip confirmationChest radiograph requiredChest radiograph requiredChest radiograph not required for tip position; confirm free aspiration and flush, and consider abdominal imaging only if malposition is suspected
        Comfort, dressing and soilingAwkward dressing; the patient cannot easily turn the headThe most comfortable and the easiest to keep clean and dressedLimits mobility; at risk of soiling in incontinence or diarrhoea; harder to keep an intact dressing

        The right internal jugular vein is preferred over the left for a first attempt: it gives a straighter course to the superior vena cava, and the thoracic duct is on the left. Where a line is placed femorally to save time in a resuscitation, that is a correct decision and not a compromise — the line is re-sited electively once the patient is stable, and the reason for the femoral choice is documented. The dominant determinant of catheter-related bloodstream infection is the asepsis of the insertion and the care of the line afterwards, not the anatomical site.

    5. 4.1.5Operator, Team and Environment:

      1. 4.1.5.1 A central venous catheter shall be inserted by a clinician who is credentialled for the procedure and for the site, or by a trainee under the direct supervision of such a clinician who is present in the room, scrubbed or immediately able to take over.

      2. 4.1.5.2 The procedure requires, as a minimum, an operator and a dedicated assistant, plus the nurse holding the checklist where the assistant is not that person. A single-handed central line insertion is not an acceptable standard outside an immediately life-threatening emergency.

      3. 4.1.5.3 The patient shall be continuously monitored throughout — electrocardiogram, oxygen saturation, non-invasive blood pressure at least every 5 minutes — with resuscitation equipment immediately available.

      4. 4.1.5.4 The procedure shall be performed in the resuscitation area or a procedure area with adequate space, light, and a bed that tilts head-down and head-up.

      5. 4.1.5.5 Where the patient is unstable, the priority order is unchanged: airway, breathing, circulation, the treatment of the cause, and only then the line. The line shall not interrupt chest compressions, haemorrhage control, decompression of a tension pneumothorax, or transfer to theatre or to the catheter laboratory.

      6. 4.1.5.6 The operator shall state, before starting, the intended site, the intended catheter, the expected depth, and the plan if the first attempt fails. Three failed attempts by one operator is the point at which the operator changes or the site changes — repeated attempts multiply mechanical complications.

    6. 4.1.6Special Populations:

      1. 4.1.6.1 Children and young people: intraosseous access, not a central line, is the emergency vascular access of choice in a shocked or arrested child. Where a central line is required, it shall be inserted by a clinician with current paediatric competence, under ultrasound, usually by the femoral route, with procedural sedation or anaesthesia (Table 5 and EMORBIT-CP-22).

      2. 4.1.6.2 Pregnancy: from the second trimester, tilt the patient left laterally or manually displace the uterus; aortocaval compression makes supine positioning and Trendelenburg poorly tolerated. The femoral vein is distended in pregnancy but the gravid uterus raises femoral venous pressure and impairs flow, so an upper-body site is generally preferred where the patient can tolerate it. Involve obstetrics.

      3. 4.1.6.3 The patient with chronic kidney disease or on dialysis: preserve the subclavian veins and the arm circulation. Discuss with nephrology before placing any catheter in a patient with an existing or planned fistula or graft. A temporary dialysis catheter is a nephrology-directed decision.

      4. 4.1.6.4 The anticoagulated patient: compressible site, ultrasound, experienced operator. Reversal is considered under EMORBIT-CP-25 where the line is urgent and the anticoagulation is significant, and shall not be given reflexively for a line that could wait.

      5. 4.1.6.5 The patient in cardiac arrest: femoral or intraosseous. Compressions are not interrupted for vascular access (EMORBIT-CP-03).

      6. 4.1.6.6 The agitated, delirious or intoxicated patient: a central line in a patient who cannot keep still is dangerous for the patient and for the operator. Treat the agitation first (EMORBIT-CP-24), use the femoral route, or defer.

      7. 4.1.6.7 The morbidly obese patient: landmarks are unreliable, the vein is deeper, and a longer needle and catheter may be required. Ultrasound is mandatory and the internal jugular route is usually the most reliable.

      8. 4.1.6.8 The patient with a tracheostomy, a cervical collar or facial and neck trauma: the neck is unavailable or contaminated; use the femoral route.

      9. 4.1.6.9

        Table 5: Paediatric considerations
        QuestionPositionPractical points
        Is a central line the right first move in a shocked child?No. Intraosseous access is the emergency vascular access of choice in a shocked or arrested child in whom peripheral access is not obtained within 2 attempts or 90 secondsEMORBIT-CP-32 (paediatric arrest). Vasopressors, fluid, blood and every resuscitation drug may be given by the intraosseous route in children
        Who inserts a central line in a child?A clinician with specific, current paediatric central venous access competence — a paediatric emergency physician, paediatric anaesthetist, paediatric intensivist or paediatric surgeon. An adult-practice operator shall not undertake a first paediatric central line in the ED except in an immediately life-threatening situation with no alternative and no such clinician availableThe complication rate in children is higher, the margin for error smaller, and the anatomy proportionally different. The named group who insert in children, and the out-of-hours route to them, should be agreed locally with paediatrics and anaesthesia
        Which site?Ultrasound-guided femoral vein is the usual site in the ED, being compressible, away from the airway and free of pneumothorax risk. Internal jugular is an alternative in experienced handsThe pleural dome is relatively higher in small children, so the subclavian route carries a proportionally greater pneumothorax risk and is not an ED route in children
        UltrasoundMandatory, with a high-frequency linear (hockey-stick) probe and the smallest appropriate footprintVessels are small, superficial and easily compressed by probe pressure — use minimal pressure or the vein will be flat and invisible
        Catheter size (guide only — confirm against stock)Neonate 3–4 Fr; infant to 10 kg 4 Fr; 10–25 kg 4–5 Fr; over 25 kg 5–7 Fr. Length selected for the site and the child’s sizeSizes are matched to the paediatric CVC kits held in the department
        Sedation and analgesiaProcedural sedation or general anaesthesia is usually required (EMORBIT-CP-22), with topical and infiltrated local anaesthetic. A struggling child is a dangerous procedureWeight-based local anaesthetic maximum doses shall be calculated and stated before infiltration
        ConfirmationAs for adults: aspiration and flush of every lumen, and a chest radiograph for any upper-body line. Tip position in children is judged relative to the carina and the cardiac silhouetteUltrasound confirmation of the wire in the vein before dilation applies with at least as much force in children
        ConsentFrom the person with parental responsibility, or in the child’s best interests in an emergency, with the reason documentedExplain to the child at a level they can understand, whatever their age
  2. 4.2Investigations:

    1. 4.2.1Before Insertion:

      1. 4.2.1.1 Pre-procedure ultrasound of the intended vein and of the alternative on the other side — the single most useful investigation. Assess patency, size, depth, compressibility, the presence of thrombus, and the position of the artery relative to the vein. It frequently changes the chosen site.

      2. 4.2.1.2 Full blood count, including the platelet count, and coagulation screen including the international normalised ratio, in every patient in whom the line is not immediately life-saving. A platelet count above 50 × 10⁹/L and an international normalised ratio below 1.5 are the conventional targets for a planned insertion.

      3. 4.2.1.3 Confirm a platelet count above 50 000 and an international normalised ratio below 1.5 if time permits (unless emergent). These are targets for a planned insertion, not thresholds below which a needed line is withheld. The published experience with ultrasound-guided insertion at compressible sites supports safe insertion at counts considerably below 50 × 10⁹/L, and correction is neither required nor always achievable before an emergency line. The threshold at which correction is expected, and the threshold below which a haematology discussion is required, are agreed with haematology and critical care.

      4. 4.2.1.4 Group and save where the coagulation is abnormal, the patient is anticoagulated, or the site is non-compressible.

      5. 4.2.1.5 A recent chest radiograph, where available, for an upper-body insertion — it identifies an existing pneumothorax, a pleural effusion, a mediastinal mass, anatomical distortion and existing devices, and prevents the catastrophic error of puncturing the side opposite a pneumothorax.

      6. 4.2.1.6 A 12-lead electrocardiogram and continuous monitoring, because guidewire-induced arrhythmia is expected and must be recognised immediately.

      7. 4.2.1.7 The weight of the patient, for local anaesthetic maximum dose and for any weight-based infusion started through the line.

    2. 4.2.2Confirmation After Insertion:

      1. 4.2.2.1 Aspirate blood freely and flush every lumen with 0.9% sodium chloride, and confirm that every lumen aspirates and flushes without resistance. A lumen that will not aspirate shall not be used for a vasopressor or a vesicant.

      2. 4.2.2.2 Confirm the catheter is venous, not arterial, before it is used. Non-pulsatile dark flow is suggestive but not conclusive in a shocked, hypoxaemic or severely acidotic patient. A blood gas taken from the catheter is a supporting test, not a definitive one, for the same reason. The definitive bedside confirmations are a transduced pressure waveform showing a venous trace, ultrasound visualisation of the catheter within the vein, or manometry.

      3. 4.2.2.3 This guideline recommends a venous blood gas sample from the catheter as additional confirmation. It is an adjunct, and it has a limitation: in a patient who is profoundly hypoxaemic, shocked or in low-output states, an arterial sample may have a venous-looking oxygen saturation, and a "venous" gas can therefore falsely reassure. A blood gas alone shall not be used to exclude arterial placement; pressure transduction and ultrasound are the definitive tests.

      4. 4.2.2.4 Chest radiograph after every internal jugular and every subclavian or axillary insertion, before the catheter is used for a concentrated infusion, to confirm tip position and to exclude pneumothorax and haemothorax.

      5. 4.2.2.5 A chest radiograph is not required for a femoral line. Confirm free aspiration and flush; consider imaging only where malposition is suspected.

      6. 4.2.2.6 Bedside lung ultrasound immediately after an upper-body insertion is faster and more sensitive than a supine chest radiograph for pneumothorax, and shall be performed where the operator is competent; it does not replace the radiograph for tip position.

      7. 4.2.2.7 In a time-critical resuscitation the line may be used before the radiograph, provided it aspirates and flushes freely and the operator is satisfied it is venous; the radiograph shall still be obtained and reviewed, and the decision documented.

    3. 4.2.3Tip Position and Malposition:

      1. 4.2.3.1 The correct tip position for an upper-body catheter is the lower third of the superior vena cava, at or just above the cavoatrial junction, with the catheter lying parallel to the wall of the vessel. On a chest radiograph this corresponds approximately to the level of the carina, or a short distance below it.

      2. 4.2.3.2 A tip within the right atrium or right ventricle shall be withdrawn. A deep tip causes arrhythmia and, rarely, perforation with tamponade.

      3. 4.2.3.3 A tip too high, in the upper superior vena cava or in a brachiocephalic vein, is unsuitable for a concentrated vasopressor or a vesicant and shall be advanced or the catheter re-sited.

      4. 4.2.3.4 A left-sided catheter must lie parallel to the wall of the superior vena cava. A left-sided tip abutting the lateral wall of the superior vena cava is at risk of erosion and shall be repositioned.

      5. 4.2.3.5 Common malpositions: into the ipsilateral internal jugular vein from a subclavian puncture; into the contralateral subclavian or brachiocephalic vein; into the azygos vein; looped within the vein; and, in a patient with a persistent left superior vena cava, down the left side of the mediastinum into the coronary sinus.

      6. 4.2.3.6 Management of a malposition: do not use the catheter for a concentrated infusion. Where the catheter is simply too deep, withdraw it to the correct depth at the skin using full aseptic precautions and repeat the radiograph. Where the tip lies in the wrong vessel, the catheter shall be removed or repositioned over a wire under imaging by a competent operator; it shall never be advanced further after the sterile field has been broken down. Every adjustment and the repeat imaging shall be documented.

      7. 4.2.3.7 A femoral catheter tip should lie in the inferior vena cava; routine imaging is not required.

  3. 4.3Plan of Care:

    1. 4.3.1Immediate Actions — Before Any Line Is Considered:

      1. 4.3.1.1 Resuscitate first. Airway, oxygenation, ventilation, haemorrhage control, decompression of an obstructive cause, and the first dose of the time-critical drug all precede vascular access planning.

      2. 4.3.1.2 Obtain the access that works now: two large-bore peripheral cannulae, an ultrasound-guided deep arm cannula, or an intraosseous needle where peripheral access fails within 2 minutes in a peri-arrest patient.

      3. 4.3.1.3 Start the vasopressor peripherally where the mean arterial pressure remains below 65 mmHg after category-appropriate initial treatment, using noradrenaline 4 mg in 250 mL (16 micrograms/mL) from 0.05 micrograms/kg/minute (EMORBIT-CP-11, EMORBIT-CP-30). Do not wait for a central line. Do not wait for a fluid volume to be completed.

      4. 4.3.1.4 Then, and only then, decide whether a central venous catheter is required, and record the indication in the notes in your own words (Table 2).

      5. 4.3.1.5 Where the answer is no, record that decision too, with the access in use and the plan for reassessment.

      6. 4.3.1.6 Where the answer is yes but the conditions are wrong, record the indication, the reason for deferral, the responsible team and the expected timeframe in the handover — as a rule within 6 hours for a patient on a peripheral vasopressor (EMORBIT-CP-11).

    2. 4.3.2The Peripheral Vasopressor and the Central Line — the Relationship Between Them:

      1. 4.3.2.1 Peripheral administration of noradrenaline is the established ED position (EMORBIT-CP-11 and EMORBIT-CP-30) and is not an irregularity to be corrected as quickly as possible. It is a safe, evidence-supported bridge with a defined technique and a defined monitoring standard.

      2. 4.3.2.2 The technique: a cannula of 20 gauge or larger, sited in a large proximal vein — upper arm preferred, then antecubital fossa, then forearm — confirmed to aspirate and flush freely, under a transparent dressing so that the site is visible at all times, dedicated to the infusion and not shared with boluses or other drugs. Not a hand, wrist or foot cannula, and never a cannula that has already tissued. The site shall be inspected and documented at least every 30 minutes, and phentolamine shall be immediately available for extravasation.

      3. 4.3.2.3 The concentration matters: 4 mg in 250 mL (16 micrograms/mL) is the peripheral bridging preparation. The 4 mg in 50 mL (80 micrograms/mL) preparation shall be given through a central line only.

      4. 4.3.2.4 At 6 hours of peripheral vasopressor administration, the requirement for a vasopressor and the need for central access shall be formally reviewed and the decision documented. Where the vasopressor is weaning, a line may not be needed at all. Where it is continuing or escalating, central access shall be arranged, in the ED or by the receiving unit.

      5. 4.3.2.5 Peripheral vasopressor administration is a temporary measure (preferably under 6 hours) until central access is established. The 6-hour figure is consistent with EMORBIT-CP-11 and is a mandatory review point, not a hard stop. A hard 6-hour limit implies that a patient whose peripheral infusion is running safely must be exposed to the risks of central venous catheterisation by the clock rather than by indication, and it re-introduces exactly the assumption — that a vasopressor requires a central line — that EMORBIT-CP-11 and EMORBIT-CP-30 were written to remove.

      6. 4.3.2.6 Dopamine is not among the agents given peripherally. EMORBIT-CP-30 states that dopamine shall not be used as a first-line vasopressor in the ED: it causes more arrhythmia than noradrenaline and was associated with increased mortality in the cardiogenic subgroup of SOAP II. Listing it here would put two ED guidelines in direct conflict.

      7. 4.3.2.7 It is established that epinephrine and vasopressin should not be administered peripherally. There is one necessary exception. Vasopressin is not started peripherally. The concentrated adrenaline infusion (4 mg in 50 mL, 80 micrograms/mL) is not given peripherally. However, the dilute adrenaline infusion used in refractory anaphylaxis — 1 mg in 100 mL (10 micrograms/mL) — is given through a peripheral line under EMORBIT-CP-01, and an unqualified prohibition here would contradict that guideline and delay treatment in anaphylaxis. The exception is stated explicitly.

      8. 4.3.2.8 A peripheral noradrenaline rate of 10 micrograms/minute is a prompt to review the access. In the weight-based units used across the ED library: for a 70 kg adult, 10 micrograms/minute is approximately 0.14 micrograms/kg/minute. EMORBIT-CP-11 and EMORBIT-CP-30 set the escalation trigger at 0.25 micrograms/kg/minute, at which point intensive care directs escalation. A single figure and a single unit apply across the department.

      9. 4.3.2.9 The requirements: a 20 gauge or larger cannula, preferably antecubital fossa or forearm (this guideline adds the upper arm as the preferred site); ultrasound guidance recommended for placement; a dedicated line with no other drug through it; hourly checks for extravasation, which this guideline increases to at least every 30 minutes in line with EMORBIT-CP-11 and EMORBIT-CP-30; and immediate cessation and phentolamine infiltration if extravasation is suspected.

      10. 4.3.2.10 Inspect for extravasation at least every 30 minutes (EMORBIT-CP-11, EMORBIT-CP-30), so that a single figure applies across the department.

      11. 4.3.2.11 Intubation is not by itself an indication for a central venous catheter, and a 2-hour clock creates a procedure without an indication. Sedative and neuromuscular blocking infusions used in the ED are given peripherally. Instead, the requirement is that the vascular access needs of every intubated patient are formally reviewed and documented within 2 hours of intubation — which ensures these patients are not forgotten — and that a line is inserted only where an indication in Table 2 is met. An arterial line, a gastric tube and a urinary catheter are considered in the intubated patient as part of the post-intubation care bundle in EMORBIT-CP-31.

    3. 4.3.3Preparation and Equipment:

      1. 4.3.3.1 Equipment assembled and checked before the field is opened: the central venous catheter kit of the correct type and length; sterile gown, gloves, cap and mask for the operator and for anyone else scrubbing; a full-length sterile drape; 2% chlorhexidine gluconate in 70% isopropyl alcohol applicators; local anaesthetic (1% or 2% lidocaine) with a fine needle; sterile 0.9% sodium chloride for flushing; needle-free connectors or caps for every lumen; a sterile transparent semi-permeable dressing and securement device; the ultrasound machine with a high-frequency linear probe, a sterile probe cover and sterile gel; a sharps container within reach of the operator; and the checklist (Attachment 3).

      2. 4.3.3.2 Catheter selection: a triple-lumen catheter where multiple incompatible infusions are required. A large-bore catheter or introducer sheath (8.5 Fr or larger) where rapid transfusion, renal replacement or transvenous pacing is the indication. A triple-lumen catheter shall not be chosen for volume resuscitation (Table 1). Catheter length is selected for the site and for the patient's size.

      3. 4.3.3.3 Positioning: supine with 10–15° Trendelenburg for an internal jugular or subclavian insertion, to distend the vein and to reduce the risk of air embolism, with the head turned slightly away and not fully rotated; supine with the leg slightly abducted and externally rotated for a femoral insertion, with reverse Trendelenburg (head up) to distend the femoral vein. Tilt the pregnant patient left laterally.

      4. 4.3.3.4 Analgesia and sedation: infiltrate local anaesthetic generously, including the deeper tissues along the intended track, and allow it to work. Procedural sedation under EMORBIT-CP-22 where the patient cannot otherwise tolerate the procedure; anaesthesia for children.

      5. 4.3.3.5 Consent: informed consent where the patient has capacity, covering purpose, alternatives (including the peripheral and intraosseous alternatives), and the risks of bleeding, arterial injury, pneumothorax, infection, arrhythmia and thrombosis — verbal or written per local policy, and documented. In an emergency, treat in the patient's best interests and document the reason afterwards.

    4. 4.3.4The Insertion Bundle and the Safe Insertion Sequence:

      1. 4.3.4.1 Every element of the insertion bundle (Table 6) applies to every insertion, every time. The bundle is not a list of desirable practices; it is the procedure.

      2. 4.3.4.2 The checklist shall be read aloud by a named team member — normally the procedural nurse — who is explicitly empowered by this guideline to stop the procedure at any point if an element is omitted or a break in asepsis occurs. The operator shall stop, correct, and resume. This authority does not depend on the seniority of the operator and shall not be questioned at the bedside.

      3. 4.3.4.3The safe insertion sequence, in order:

        • Pre-scan both intended veins before draping: patency, size, depth, compressibility, thrombus, and the position of the artery.
        • Position the patient and the ultrasound screen so the operator looks along the needle at the screen without turning the head.
        • Hand hygiene, then cap, mask, sterile gown and sterile gloves for everyone scrubbing.
        • Skin antisepsis with 2% chlorhexidine in 70% alcohol, with friction, for 30 seconds, over a wide area — then let it dry: at least 30 seconds on the neck or chest, at least 2 minutes on the groin. Do not puncture a wet field.
        • Full-length sterile drape with a fenestration at the site.
        • Prepare the kit on the field: flush every lumen, check the wire runs freely in its dispenser, and check the catheter length against the intended depth.
        • Local anaesthetic infiltrated and given time to work.
        • Real-time ultrasound-guided puncture, short axis for orientation and needle-tip tracking, long axis to confirm the needle within the vein, with the needle tip visualised at all times. Aspirate dark, non-pulsatile blood.
        • Pass the guidewire gently. It shall never be forced. Limit insertion to approximately 15–20 cm. Watch the monitor for ectopy and withdraw the wire immediately if it appears.
        • CONFIRM THE WIRE IS IN THE VEIN BEFORE THE DILATOR TOUCHES THE SKIN. Visualise the wire inside the vein lumen on ultrasound, in long axis where possible, and confirm the artery is empty of wire. Transduce a pressure waveform where there is any doubt. This step is not optional and is not omitted for speed.
        • Nick the skin, then dilate — only the depth required, over the wire, with the wire held and moving freely at all times.
        • Rail-road the catheter over the wire, holding the wire proximally, and remove the wire completely — then show it, intact, to the assistant and say so aloud.
        • Aspirate and flush every lumen; cap or connect every lumen.
        • Secure and dress the catheter; record the depth at the skin.
        • Confirm position (section 4.2.2), complete the insertion record (Attachment 3), and dispose of sharps yourself.
      4. 4.3.4.4 Three failed attempts by one operator is the limit. Change the operator, change the site, or reconsider whether the line is needed. Repeated attempts increase mechanical complications disproportionately.

      5. 4.3.4.5 This guideline requires ultrasound guidance as mandatory for internal jugular and femoral vein access, maximal sterile barriers, and 2% chlorhexidine in 70% alcohol. Ultrasound guidance is mandatory at every site including the infraclavicular axillary approach, and the technique includes the chlorhexidine drying time, confirmation of the wire within the vein before dilation, and a read-aloud checklist with a nurse empowered to stop the procedure. The last two are the elements most strongly associated with harm when absent.

      6. 4.3.4.6

        Table 6: The insertion bundle — every element, every time, with the step that is routinely omitted marked
        ElementWhat it means in practiceWhy it is in the bundle
        1. Documented indication and consentThe indication written in the record before the procedure. Informed consent where the patient has capacity: purpose, alternatives, and the risks of bleeding, arterial injury, pneumothorax, infection, arrhythmia and thrombosis. In an emergency, treatment in the patient’s best interests with the reason documented afterwardsFewer lines are inserted when the indication has to be written down. This is the first defence against the reflex line
        2. Hand hygieneFull hand hygiene immediately before donning sterile attire, and again for any glove changeThe single most effective infection prevention measure; repeatedly the most frequently omitted
        3. Maximal sterile barrier precautionsFor the operator and the assistant scrubbing: cap, mask, sterile gown, sterile gloves. For the patient: a full-length sterile drape covering the patient from head to toe with a fenestration at the site — not a small square towelMaximal barriers reduce catheter-related bloodstream infection several-fold compared with gloves and a small drape. The full-length drape is the element most often reduced to a hand towel
        4. Skin antisepsis AND ITS DRYING TIME2% chlorhexidine gluconate in 70% isopropyl alcohol, applied with friction using a back-and-forth motion for 30 seconds, over an area far wider than the drape fenestration. Then allow it to dry completely before puncture: at least 30 seconds on a dry site (neck, chest) and at least 2 minutes on a moist site (groin, axilla). Do not fan, blot or wipe it dry. Where chlorhexidine is contraindicated, use povidone-iodine in alcohol and allow a longer drying timeThis is the step that is routinely ignored. Chlorhexidine kills organisms while it dries; puncturing a wet field inoculates the tract with skin flora and wastes the antisepsis entirely. It also removes a fire risk where diathermy may follow. The drying time is not a delay in the procedure — it is the procedure
        5. Optimal site selectionThe site chosen and recorded against Table 4, with the reason where a resuscitation site is usedSite selection changes infection, thrombosis and mechanical risk, and is a deliberate decision, not a habit
        6. Real-time ultrasound guidancePre-scan both sides before draping — vein patency, size, depth, compressibility, thrombus and the position of the artery. Then real-time guidance for the puncture, with a sterile probe cover and sterile gelUltrasound guidance reduces failed cannulation, the number of attempts and arterial puncture. It is the standard of care (NICE TA49)
        7. Confirm the guidewire is in the vein BEFORE dilatingBefore the dilator is loaded: visualise the wire inside the vein lumen on ultrasound, in long axis wherever possible, and confirm that the artery contains no wire. Where there is any doubt, confirm by transduced pressure waveform or by a manometry column through the cannula. Limit wire insertion to approximately 15–20 cm and watch the monitorThis is the single step that prevents the catastrophe of this procedure. An arterial puncture with a needle is a nuisance; an artery that has been dilated and catheterised is a surgical emergency. The dilator is the point of no return
        8. Aseptic non-touch technique throughoutSterile field maintained, key parts protected, no unsterile hand crossing the field, and the assistant not leaning over it. A break in asepsis is called and corrected, not ignoredEvery break is an inoculation
        9. A checklist, read aloud, with a nurse empowered to stop the procedureOne named team member — normally the procedural nurse — holds the checklist (Attachment 3), reads it aloud, and has the explicit authority of this guideline and of the head of department to halt the procedure at any point if an element is omitted or a break in asepsis occurs. The operator shall stop, correct and resume. The nurse does not need the operator’s permission to speakThis is the element that made the central line bundle work. In the original Keystone work the checklist plus explicit nursing authority to stop the procedure reduced catheter-related bloodstream infection close to zero and held it there. A checklist nobody is empowered to enforce is paperwork
        10. Sterile dressing and securementA sterile, transparent, semi-permeable dressing over a clean, dry site, applied without tension; a sterile gauze dressing where the site is bleeding or oozing, changed at 24–48 hours and converted to transparent once dry. Sutureless securement device or sutures as per local practiceThe dressing maintains the barrier the insertion created
        11. Confirmation and documentationAspiration and flush of every lumen; confirmatory imaging where required (section 4.3.6); the insertion record completed (Attachment 3)An unconfirmed line is an unusable line
        12. Daily review of necessity, starting the day it is insertedThe question "does this line still need to be here?" is asked at every handover from the moment of insertion, including the ED handover to the admitting teamCatheter-related bloodstream infection risk accumulates with every catheter-day. The most effective prevention is removal

        Where any element of this bundle is omitted because the insertion is a true emergency, that fact shall be recorded explicitly in the notes at the time, and the catheter shall be treated as a contaminated line: it shall be removed and, if still needed, replaced at a new site under full asepsis as soon as the patient is stable, and in any event within 48 hours. The replacement is the responsibility of the team caring for the patient at that time, and the requirement shall be stated in the ED handover.

    5. 4.3.5Complications and Their Immediate Management:

      1. 4.3.5.1 Arterial puncture with the needle — withdraw and compress firmly for at least 10 minutes; reassess before any further attempt.

      2. 4.3.5.2 Arterial dilation or cannulation — the catastrophe of this procedure. DO NOT REMOVE THE CATHETER. Leave it in situ and clamped, call vascular surgery and interventional radiology immediately, keep the patient in the resuscitation area, and report it as a serious incident. Removing a dilated arterial catheter converts a controlled injury into uncontrollable haemorrhage.

      3. 4.3.5.3 Pneumothorax — bedside lung ultrasound; immediate decompression for tension; drain or observe according to size, symptoms and the need for positive-pressure ventilation. Never attempt the contralateral side. Suspect pneumothorax in a patient who becomes dyspnoeic; lung ultrasound is the faster first test, and an immediate chest radiograph follows.

      4. 4.3.5.4 Air embolism — occlude the hub, place the patient head-down in the left lateral decubitus position, give 100% oxygen, aspirate air from the distal lumen where a catheter is in place, and resuscitate. Prevented by Trendelenburg positioning for upper-body insertion, by occluding the needle hub and the catheter hub at every step, and by correct removal technique (Table 8).

      5. 4.3.5.5 Guidewire-induced arrhythmia — withdraw the wire a few centimetres; it almost always stops immediately. Continuous monitoring is mandatory.

      6. 4.3.5.6 Haematoma — direct pressure; a neck haematoma is an airway emergency and requires early senior airway help.

      7. 4.3.5.7 Retained, sheared or lost guidewire — a NEVER EVENT. The wire is held at all times, is removed complete, and is shown intact to the assistant and counted before the drapes come off. Where it is not accounted for: immediate imaging, interventional retrieval, duty of candour, and a serious incident report.

      8. 4.3.5.8 Catheter-related bloodstream infection — paired blood cultures, one set through the catheter and one peripheral, both labelled with site and time; remove the catheter where there is septic shock, purulence or no other source, and send the tip for culture; start empirical antibiotics per the ED antimicrobial stewardship protocol and the local antibiogram.

      9. 4.3.5.9 Empirical vancomycin plus piperacillin-tazobactam, adjusted by culture, is used for catheter-related bloodstream infection. The regimen is not stated as a fixed regimen in this guideline, because antibiotic selection is governed by the ED antimicrobial stewardship protocol and the current local antibiogram and changes with them. Clinical Pharmacy and Infection Prevention and Control shall confirm the regimen, the dosing in renal impairment, and the local extended-spectrum beta-lactamase and meticillin-resistant Staphylococcus aureus considerations before use.

      10. 4.3.5.10

        Table 7: Complications — recognition and immediate management
        ComplicationRecognitionImmediate management
        Arterial puncture (needle only)Pulsatile bright red flow; ultrasound shows the needle in the artery; a transduced arterial waveformWithdraw the needle. Apply firm continuous direct pressure for at least 10 minutes (longer if coagulopathic or anticoagulated), then re-examine. Observe for an expanding haematoma, airway compromise in the neck, and distal ischaemia. Reassess before any further attempt, and consider a different site and a more experienced operator. Document it
        Arterial dilation or cannulation (dilator or catheter in the artery)Pulsatile flow from the catheter; bright red blood; a transduced arterial waveform; an unexpectedly high oxygen saturation on a sample; a catheter seen crossing an artery on imaging. This may only become apparent after the procedure — a high index of suspicion is required in any difficult insertionDO NOT REMOVE THE CATHETER. Removing it converts a controlled injury into uncontrollable bleeding into the chest, neck or retroperitoneum, and is the mechanism by which this complication kills. Leave the catheter in situ and clamped. Call vascular surgery and interventional radiology immediately, and inform the anaesthetic and critical care teams. Removal is performed with surgical or endovascular control of the vessel. Keep the patient in the resuscitation area, group and save, and monitor continuously. Report as a serious incident
        PneumothoraxDyspnoea, hypoxaemia, pleuritic pain, reduced air entry, surgical emphysema, rising airway pressures in a ventilated patient, or an abnormal post-procedure radiograph. May be delayed by several hoursImmediate bedside lung ultrasound (absent lung sliding, a lung point) is faster and more sensitive than a supine chest radiograph. Tension pneumothorax: immediate decompression before any imaging. Otherwise, intercostal drain or observation depending on size, symptoms and whether positive-pressure ventilation is required. Do not attempt the contralateral side
        Air embolismSudden dyspnoea, hypoxaemia, hypotension, chest pain, altered consciousness or cardiovascular collapse during insertion, during a disconnection, or on removal. A "mill-wheel" murmur is described and is rarely heardImmediately occlude the hub or the open lumen. Place the patient head-down in the left lateral decubitus position (Durant manoeuvre) to trap air at the apex of the right ventricle. Give 100% oxygen. Where a central catheter is in place, attempt aspiration of air from the distal lumen. Resuscitate as required; call critical care. Hyperbaric oxygen may be considered for cerebral arterial gas embolism after senior discussion
        Guidewire-induced arrhythmiaVentricular ectopy, ventricular tachycardia or bradycardia appearing as the wire is advancedWithdraw the wire a few centimetres — the arrhythmia almost always stops immediately. Limit wire insertion to approximately 15–20 cm. Continuous electrocardiographic monitoring is mandatory throughout the procedure. Treat a sustained arrhythmia under EMORBIT-CP-03
        HaematomaSwelling, bruising or expansion at the site; in the neck, hoarseness, stridor, dysphagia or tracheal deviationDirect pressure. A neck haematoma is an airway emergency: call for senior airway and anaesthetic help early, sit the patient up unless contraindicated, prepare for a difficult airway, and do not wait for stridor. Check coagulation and reverse anticoagulation where indicated (EMORBIT-CP-25)
        Retained, sheared or lost guidewireThe wire is not accounted for at the end of the procedure. The wire shall be held at all times and shall be physically shown, intact, to the assistant and counted before the drapes come offThis is a NEVER EVENT. Do not manipulate further. Obtain immediate imaging to locate the wire or fragment, call interventional radiology or cardiology for retrieval, keep the patient monitored, inform the patient and family under the duty of candour, and report immediately through the local incident reporting system with a departmental review
        Catheter malpositionThe catheter tip is not in the lower superior vena cava on the confirmatory radiograph — it may be in the contralateral subclavian, the internal jugular, the azygos vein, the right atrium or ventricle, or loopedDo not use a malpositioned catheter for a concentrated vasopressor or a vesicant. Withdraw to the correct depth where the malposition is simple over-insertion. Where the tip is in the wrong vessel, the catheter shall be removed or repositioned under imaging; it shall not be advanced further from outside the sterile field. Repeat the radiograph after any adjustment and document it
        Catheter-related bloodstream infectionNew fever, rigors (classically on flushing the line), sepsis without another source, or purulence, tenderness or erythema at the exit site, in a patient with a central catheterTake paired blood cultures — one set through the catheter and one set peripherally, labelled with site and time (EMORBIT-CP-11). Remove the catheter where there is septic shock, purulence or a tunnel infection, or where no other source is found, and send the tip for culture. Start empirical antibiotics per the ED antimicrobial stewardship protocol and the local antibiogram
        Catheter-related thrombosisLimb, neck or facial swelling; a distended collateral venous pattern; pain; a catheter that will not aspirateUltrasound with compression. Discuss anticoagulation with the admitting team; catheter removal is usually indicated where the line is no longer needed, and is not by itself an emergency in the ED
        Cardiac tamponade from catheter tip perforationSudden hypotension, distended neck veins, muffled heart sounds, electrical alternans, in a patient with a recently placed catheter whose tip was deep or against a wallRare but rapidly fatal. Bedside echocardiography; do not remove the catheter — aspirate from it, and perform urgent pericardiocentesis; call cardiothoracic surgery. Prevented by correct tip position (section 4.3.6)

        Every complication shall be documented in the insertion record and reported through the local incident reporting system. Arterial dilation or cannulation, retained guidewire, tamponade, air embolism and any death or serious harm are reportable as serious incidents and shall be reviewed at the departmental morbidity and mortality meeting.

    6. 4.3.6Care of the Line While the Patient Remains in the Emergency Department:

      1. 4.3.6.1 The insertion site shall be inspected at least every 4 hours while the patient is in the ED, and at every handover, and the dressing shall be intact, dry and adherent. A loose, damp, soiled or blood-stained dressing shall be changed using an aseptic technique.

      2. 4.3.6.2 Scrub the hub. Every needle-free connector shall be decontaminated with a 2% chlorhexidine in 70% alcohol wipe, with friction, for at least 15 seconds, and allowed to dry, before every single access. This is the commonest route of contamination of a line that was inserted correctly.

      3. 4.3.6.3 Minimise the number of lumens used and the number of accesses. Where a vasopressor is running, dedicate a lumen to it and label it.

      4. 4.3.6.4 Label every lumen at the hub with what is running through it. Label the vasopressor lumen distinctly.

      5. 4.3.6.5 Flush unused lumens with 0.9% sodium chloride using a pulsatile technique and positive pressure on disconnection, in accordance with the local infusion therapy standard.

      6. 4.3.6.6 Do not use a lumen that does not aspirate for a vasopressor or a vesicant.

      7. 4.3.6.7 Review the necessity of the line at every handover, starting with the handover that follows its insertion. The question is "does this still need to be here?" and the answer is recorded.

      8. 4.3.6.8 A line placed in an emergency without the full aseptic bundle shall be recorded as such at the time, and shall be removed and — if still needed — replaced at a new site under full asepsis as soon as the patient is stable and in any event within 48 hours. This requirement shall be stated explicitly in the ED handover to the receiving team, and the receiving team shall confirm they have received it. Guidewire exchange at the same site does not correct a contaminated insertion.

      9. 4.3.6.9 Inspect the site daily for signs of infection, and change the dressing every 7 days or sooner if it becomes soiled, damp or loose; a gauze dressing over a bleeding or oozing site is changed at 24–48 hours and converted to a transparent dressing once the site is dry.

    7. 4.3.7Monitoring and Reassessment:

      1. 4.3.7.1 Continuous electrocardiographic monitoring, oxygen saturation and blood pressure at least every 5 minutes during the procedure and for at least 30 minutes afterwards.

      2. 4.3.7.2 Reassess specifically for the delayed complications: new dyspnoea, hypoxaemia or chest pain (pneumothorax, which may appear hours later); expanding neck swelling, hoarseness or stridor (haematoma); new arrhythmia; and limb, neck or facial swelling (thrombosis).

      3. 4.3.7.3 Where a concentrated infusion is started through the line, confirm the tip position first, and reassess the patient's haemodynamics after every rate change.

      4. 4.3.7.4 Any unexplained deterioration in a patient with a recently inserted central venous catheter shall prompt reconsideration of pneumothorax, haemothorax, arterial injury, tamponade and air embolism before it is attributed to the underlying illness.

    8. 4.3.8Removal:

      1. 4.3.8.1 Remove the line when it is no longer needed. This is the most effective single measure against catheter-related bloodstream infection, and the necessity question is asked from the day of insertion.

      2. 4.3.8.2 Remove a line inserted without full asepsis, and replace it at a new site if still required, within 48 hours.

      3. 4.3.8.3 Remove for suspected catheter-related bloodstream infection where there is septic shock, purulence at the exit site, a tunnel infection, or no other source; send the tip for culture.

      4. 4.3.8.4 Removal technique for an upper-body line — the air embolism prevention steps are not optional: lay the patient flat or 10–15° head-down; ask the patient to breathe in, hold and bear down, or remove at end-inspiration in a ventilated patient; withdraw smoothly without force; apply immediate digital pressure for at least 5 minutes; apply an air-occlusive dressing that remains in place for at least 24 hours; and keep the patient supine for 30 minutes.

      5. 4.3.8.5 Never pull against resistance. Stop, reposition, warm the area, and seek senior or interventional advice.

      6. 4.3.8.6 Inspect the removed catheter and confirm it is complete against its stated length. A missing segment is an emergency requiring immediate imaging and retrieval.

      7. 4.3.8.7

        Table 8: Removal — indications and the technique that prevents air embolism
        StepWhat to do
        INDICATIONS FOR REMOVAL
        The line is no longer neededThe commonest and most important indication. Asked at every handover from the moment of insertion
        Inserted without full asepsisRemove and, if still required, replace at a new site under full asepsis as soon as the patient is stable and within 48 hours. Guidewire exchange at the same site does not correct a contaminated insertion
        Suspected catheter-related bloodstream infectionRemove where there is septic shock, purulence at the exit site, a tunnel infection, or no other source found. Send the tip for culture with paired blood cultures already taken
        Mechanical failure, malposition or catheter-related thrombosis with limb compromiseRemove or re-site as clinically indicated
        REMOVAL TECHNIQUE — UPPER BODY LINES
        PositionLay the patient flat, or 10–15° head-down. Never remove a jugular or subclavian catheter with the patient sitting up: the exit site is then above the level of the right atrium and air is drawn in
        BreathingAsk the patient to take a breath in, hold it and bear down (Valsalva) — or, if ventilated, remove at end-inspiration — and withdraw the catheter during that manoeuvre, smoothly and without force
        Sealing the tractApply immediate digital pressure for at least 5 minutes (longer if coagulopathic), then an air-occlusive dressing — a sterile gauze with an occlusive film, or a petroleum-based dressing — which stays in place for at least 24 hours. The tract does not seal instantly, and late air embolism occurs after the dressing is removed too early
        AfterwardsKeep the patient flat or supine for 30 minutes. Inspect the catheter and confirm it is intact and complete against its stated length; a missing segment is an emergency requiring imaging and retrieval. Document removal, the reason, the integrity of the catheter and any specimen sent
        ResistanceNever pull against resistance. Stop, reposition the limb or the patient, apply a warm compress, and seek senior or interventional advice — a catheter may be adherent, knotted or entrapped
    9. 4.3.9Disposition and Handover:

      1. 4.3.9.1Critical care (level 3) referral:

        • Any patient in whom a central venous catheter has been inserted for shock, vasopressor requirement or renal replacement, in accordance with EMORBIT-CP-11 and EMORBIT-CP-30.
        • Any patient who has sustained a significant procedural complication — arterial dilation, pneumothorax requiring drainage, air embolism, tamponade or a retained guidewire.
      2. 4.3.9.2Admission to a ward with a central venous catheter in place:

        • Only where the receiving ward is competent and equipped to care for the device, the confirmatory imaging has been reviewed and documented, and the necessity review arrangement has been handed over.
        • Where a line was placed without full asepsis, the requirement to replace it within 48 hours shall be stated in the handover and accepted by the receiving team.
      3. 4.3.9.3Discharge from the ED with a central venous catheter in place:

        • Shall not occur. A patient who no longer needs the line shall have it removed before discharge, using the technique in Table 8, and shall be observed for 30 minutes afterwards.
      4. 4.3.9.4 The structured (SBAR) handover shall include: the indication for the line; the site, the catheter type and the depth at the skin; the date and time of insertion; whether the full aseptic bundle was completed or not, and if not, the deadline for replacement; the confirmatory imaging and its result; any complication; what is running through which lumen; and the plan for review of necessity.

      5. 4.3.9.5 Where a line was considered and not inserted, the handover shall state the access in use, the reason the line was deferred, the responsible team and the expected timeframe.

    10. 4.3.10Documentation and the Insertion Record:

      1. 4.3.10.1 An insertion record (Attachment 3) shall be completed for every central venous catheter inserted in the ED, filed in the medical record, and copied to the ED quality team for audit against the indicators in section 11.

      2. 4.3.10.2The record shall state:

        • The indication, in the operator's own words, and why peripheral and intraosseous access would not serve.
        • Consent obtained, or treatment in the patient's best interests with the reason.
        • The operator and grade, the supervising clinician where applicable, and the assistant and the checklist holder.
        • The platelet count and international normalised ratio where obtained, or the reason they were not.
        • The site, the side, the catheter type, gauge or French size, the number of lumens, and the length.
        • Ultrasound used: yes or no — and, if no, the reason.
        • Confirmation that the guidewire was visualised within the vein before dilation.
        • The number of skin punctures and of attempts.
        • Every element of the insertion bundle, ticked or explicitly marked as omitted, including the chlorhexidine drying time.
        • The guidewire removed intact and counted.
        • The depth at the skin, aspiration and flush of every lumen, and the dressing applied.
        • The confirmatory imaging requested, the time it was performed, and the reported tip position.
        • Any complication and its management.
        • Where the full aseptic bundle was not completed: an explicit statement to that effect and the date and time by which the catheter is to be replaced.
      3. 4.3.10.3 Where a central venous catheter was considered and not inserted, the decision and its reasoning shall also be documented — this is as much a part of the standard as the insertion record.

      4. 4.3.10.4 Every mechanical complication, every never event, every catheter-related bloodstream infection attributed to an ED-inserted line, and every unplanned replacement of a line placed without asepsis shall be reported through the local incident reporting system and reviewed at the departmental morbidity and mortality meeting.

5Algorithm

The one-page algorithm is shown at the top of this page.

6Team roles

  1. 6.1Triage Nurse:

    1. 6.1.1 Recognise the patient who needs immediate vascular access and move them to the resuscitation area; establish peripheral access and take bloods on arrival.

    2. 6.1.2 Record whether the patient has an existing central venous catheter, a dialysis fistula or graft, or a pacemaker, and alert the treating physician — each of these changes vascular access decisions.

  2. 6.2ED Nurses:

    1. 6.2.1 Hold the insertion checklist, read it aloud, and stop the procedure where an element is omitted or asepsis is broken. This authority is granted by this guideline and by the head of department and does not require the operator's agreement.

    2. 6.2.2 Assemble and check the equipment and the trolley before the field is opened; ensure the sterile probe cover, sterile gel and full-length drape are present.

    3. 6.2.3 Inspect a peripheral vasopressor site at least every 30 minutes and know where the phentolamine is kept.

    4. 6.2.4 Inspect a central venous catheter site at least every 4 hours and at every handover; keep the dressing intact, dry and adherent.

    5. 6.2.5 Scrub the hub for at least 15 seconds and allow it to dry before every access; label every lumen.

    6. 6.2.6 Monitor the patient continuously during and for 30 minutes after the procedure; report new dyspnoea, chest pain, arrhythmia, neck swelling or hypotension immediately.

    7. 6.2.7 Complete the nursing sections of the insertion record and ensure the confirmatory imaging has been requested and reviewed.

    8. 6.2.8 Ask, at every handover, whether the line is still needed.

  3. 6.3Clinical Pharmacist:

    1. 6.3.1 Identify which preparations on the local formulary require central administration and which have a peripherally administrable alternative for the ED phase.

    2. 6.3.2 Verify vasopressor concentrations and ensure the 16 micrograms/mL peripheral and 80 micrograms/mL central noradrenaline preparations are clearly distinguished, labelled and stocked separately.

    3. 6.3.3 Ensure phentolamine is stocked and its location known, and advise on extravasation management.

    4. 6.3.4 Advise on empirical antibiotic therapy for suspected catheter-related bloodstream infection against the current antibiogram and the ED antimicrobial stewardship protocol.

  4. 6.4Critical Care:

    1. 6.4.1 Attend at the bedside within 30 minutes of referral for any patient in shock requiring a vasopressor (EMORBIT-CP-11, EMORBIT-CP-30), and advise on whether central access is required in the ED or after transfer.

    2. 6.4.2 Accept and continue the necessity review of any line inserted in the ED, and act on the replacement deadline for a line inserted without full asepsis.

    3. 6.4.3 Provide, with anaesthesia, the credentialling standard and the supervised training pathway for ED operators.

  5. 6.5Anaesthesia:

    1. 6.5.1 Assist with a difficult insertion, with an airway compromised by a neck haematoma, and with paediatric insertion and sedation.

    2. 6.5.2 Participate in the departmental credentialling of central venous access and in the simulation programme.

  6. 6.6Infection Prevention and Control:

    1. 6.6.1 Own the insertion bundle, the audit of bundle compliance, and the surveillance definition and reporting of catheter-related bloodstream infection attributable to ED-inserted lines.

    2. 6.6.2 Confirm the skin antisepsis agent, the application technique and the drying times to be used locally, and confirm the dressing and hub decontamination standards.

    3. 6.6.3 Feed bundle compliance and infection data back to the department at least quarterly.

  7. 6.7Vascular Surgery and Interventional Radiology:

    1. 6.7.1 Respond immediately to a catheter that has been dilated into an artery. Removal is performed with surgical or endovascular control; the catheter is not removed before they arrive.

    2. 6.7.2 Retrieve a retained or sheared guidewire or catheter fragment.

    3. 6.7.3 Advise on and provide access in the patient with exhausted or distorted venous anatomy.

  8. 6.8Nephrology:

    1. 6.8.1 Direct the placement of temporary dialysis access and advise on preservation of the subclavian veins and the arm circulation in any patient with, or approaching, long-term dialysis.

  9. 6.9Paediatrics:

    1. 6.9.1 Provide, with anaesthesia, the named clinicians who insert central venous catheters in children and the out-of-hours route to them; share the care of every child in whom central access is required.

  10. 6.10Radiology:

    1. 6.10.1 Provide and report the confirmatory chest radiograph promptly, reporting the tip position explicitly and reporting a pneumothorax or a malposition verbally as a critical finding.

  11. 6.11Laboratory and Microbiology:

    1. 6.11.1 Process paired blood cultures with the site and time preserved, and catheter tip cultures; report positives verbally.

  12. 6.12Ambulance and Pre-hospital Providers:

    1. 6.12.1 Establish and hand over peripheral or intraosseous access with the site, gauge, time of placement and what has run through it; report any vasopressor started and its rate and access site.

7The patient's role

  1. 7.1 Tell the team about previous central lines, difficult vascular access, a dialysis fistula or graft, a pacemaker, previous thrombosis, and any allergy — particularly to chlorhexidine, iodine, latex or local anaesthetic.

  2. 7.2 Tell the team about blood thinners and about any bleeding tendency.

  3. 7.3 Ask what the line is for, what the alternatives are, and what the risks are; consent or decline, and say if the explanation is not clear.

  4. 7.4 Lie as still as possible during the procedure, keep the head in the position asked for, and follow the instructions about breathing and about holding a breath.

  5. 7.5 Tell staff immediately about breathlessness, chest pain, palpitations, pain or swelling at the site, or pain or burning at any drip site.

  6. 7.6 Do not touch, pull or adjust the line or the dressing, and tell staff if the dressing becomes loose, wet or dirty.

  7. 7.7 During removal, follow the instruction to lie flat and to breathe in and bear down, and remain lying flat afterwards for as long as asked.

  8. 7.8 Leave the dressing over the removal site in place for at least 24 hours, and return if the site bleeds, becomes red or painful, or if fever develops.

8Definitions

  1. 8.1Central Venous Catheter (CVC): a catheter whose tip lies within a great vein — for upper-body access, the lower third of the superior vena cava at or just above the cavoatrial junction; for femoral access, the inferior vena cava.

  2. 8.2Midline Catheter: a peripherally inserted catheter 8–20 cm long whose tip lies in the axillary vein at or below the level of the axilla. It is not a central venous catheter and shall not be used for vasopressors or vesicants.

  3. 8.3Peripherally Inserted Central Catheter (PICC): a central venous catheter inserted through an arm vein with its tip in the superior vena cava, placed by a vascular access or radiology service for medium-term therapy.

  4. 8.4Peripheral Vasopressor: a vasoactive infusion administered through a large proximal peripheral vein as a bridge, with defined site selection, concentration, monitoring and review (EMORBIT-CP-11, EMORBIT-CP-30).

  5. 8.5Intraosseous Access: vascular access obtained by inserting a needle into the medullary cavity of a bone, reaching the central circulation within seconds; suitable for every resuscitation drug including vasopressors, and intended as a bridge for up to 24 hours.

  6. 8.6Insertion Bundle: the defined set of evidence-based elements applied together at every insertion — hand hygiene, maximal sterile barrier precautions, chlorhexidine skin antisepsis with its drying time, optimal site selection, ultrasound guidance, confirmation of the wire before dilation, a read-aloud checklist with authority to stop, and daily review of necessity.

  7. 8.7Maximal Sterile Barrier Precautions: cap, mask, sterile gown and sterile gloves for everyone scrubbed, and a full-length sterile drape covering the patient from head to toe with a fenestration at the insertion site.

  8. 8.8Short Axis (Out-of-Plane) Technique: the ultrasound probe is held transverse to the vessel, which appears as a circle; the needle crosses the beam and is seen as a bright dot. Easier for orientation and for seeing the artery and vein together; the needle tip must be tracked deliberately, because the bright dot may be the shaft.

  9. 8.9Long Axis (In-Plane) Technique: the probe is held along the vessel, which appears as a tube; the entire needle including the tip is seen throughout its course. Harder to learn, but it shows the needle tip unambiguously and is the technique used to confirm the guidewire within the vein.

  10. 8.10Cavoatrial Junction: the point at which the superior vena cava meets the right atrium; the target zone for an upper-body catheter tip, approximated on a chest radiograph by the level of the carina or a short distance below it.

  11. 8.11Catheter-Related Bloodstream Infection (CRBSI): bloodstream infection in a patient with an intravascular catheter, where the catheter is demonstrated to be the source, including by differential time to positivity between paired catheter and peripheral cultures or by catheter tip culture.

  12. 8.12Central Line-Associated Bloodstream Infection (CLABSI): the surveillance definition — a laboratory-confirmed bloodstream infection in a patient with a central line in place for more than 2 calendar days, with no other identified source. Used for reporting; not identical to the clinical diagnosis of CRBSI.

  13. 8.13Never Event: a serious, largely preventable patient safety incident that should not occur if the available preventive measures have been implemented. A retained guidewire after central venous catheterisation is a never event.

  14. 8.14Durant Manoeuvre: placing a patient with suspected venous air embolism head-down in the left lateral decubitus position, to trap air at the apex of the right ventricle and away from the right ventricular outflow tract.

  15. 8.15epic3, NICE, INS, SCCM, ESICM, ASA, SHEA, IDSA: epic3 National Evidence-Based Guidelines for Preventing Healthcare-Associated Infections; National Institute for Health and Care Excellence; Infusion Nurses Society; Society of Critical Care Medicine; European Society of Intensive Care Medicine; American Society of Anesthesiologists; Society for Healthcare Epidemiology of America; Infectious Diseases Society of America.

9Attachments

11Suggested quality indicators

  1. 11.1Indication documented (process): (Number of central venous catheters inserted in the ED for which a written indication is recorded in the insertion record before the procedure / Total number of central venous catheters inserted in the ED) × 100. Target 100%.

  2. 11.2Ultrasound used (process): (Number of central venous catheters inserted in the ED under real-time ultrasound guidance / Total number of central venous catheters inserted in the ED) × 100. Target ≥ 98%. Every insertion without ultrasound shall be individually reviewed.

  3. 11.3Insertion bundle completed (process): (Number of ED central venous catheter insertions in which every element of the insertion bundle, including the chlorhexidine drying time and confirmation of the guidewire within the vein before dilation, is documented as completed / Total number of ED central venous catheter insertions, excluding those explicitly recorded as emergency insertions without full asepsis) × 100. Target ≥ 95%.

  4. 11.4Confirmatory imaging documented (safe disposition): (Number of ED-inserted internal jugular, subclavian and axillary catheters for which a confirmatory chest radiograph with a reported tip position is documented before the patient leaves the ED, or before the catheter is used for a concentrated infusion, whichever is earlier / Total number of such catheters inserted in the ED) × 100. Target ≥ 95%.

  5. 11.5Vasopressor not delayed for central access (time-to-treatment): (Number of patients in whom a vasopressor was started within 30 minutes of the documented decision that the mean arterial pressure remained below 65 mmHg despite category-appropriate initial treatment, without waiting for central venous access / Total number of patients in whom a vasopressor was indicated) × 100. Target ≥ 90%. This indicator exists to detect the reintroduction of the practice of waiting for a central line and is reported jointly with EMORBIT-CP-11 and EMORBIT-CP-30.

  6. 11.6Lines placed without full asepsis and replaced on time (process): (Number of catheters recorded as inserted without the full aseptic bundle that were removed or replaced within 48 hours / Total number of catheters recorded as inserted without the full aseptic bundle) × 100. Target 100%.

  7. 11.7Mechanical complication (outcome): (Number of ED-inserted central venous catheters complicated by pneumothorax, haemothorax, arterial puncture requiring intervention, arterial dilation or cannulation, air embolism, tamponade or retained guidewire / Total number of ED-inserted central venous catheters) × 100. Monitored and trended against the published benchmark of approximately 1 to 3 per cent for ultrasound-guided insertion; every case is individually reviewed, and arterial dilation, retained guidewire, tamponade and air embolism are reported as serious incidents.

  8. 11.8Catheter-related bloodstream infection (outcome): Number of catheter-related bloodstream infections attributable to ED-inserted central venous catheters per 1000 catheter-days, reported with Infection Prevention and Control using the agreed surveillance definition. Monitored and trended; the departmental aim is zero and the local threshold for formal review shall be agreed with Infection Prevention and Control.

  9. 11.9Outcome and balancing indicators (monitored, no fixed target): the number of central venous catheters inserted in the ED per 1000 resuscitation-area attendances, trended — a falling rate with unchanged outcomes is the intended effect of this guideline; the proportion of insertions requiring more than three attempts or a change of operator; the proportion of femoral lines re-sited within 72 hours; and the number of peripheral vasopressor extravasation events, reported jointly with EMORBIT-CP-11 and EMORBIT-CP-30.

13References

  1. Loveday HP, Wilson JA, Pratt RJ, et al. epic3: National Evidence-Based Guidelines for Preventing Healthcare-Associated Infections in NHS Hospitals in England. J Hosp Infect. 2014;86(Suppl 1):S1–S70.
  2. National Institute for Health and Care Excellence. Healthcare-associated infections: prevention and control in primary and community care. Clinical guideline CG139. London: NICE; 2012 (updated 2017).
  3. National Institute for Health and Care Excellence. Guidance on the use of ultrasound locating devices for placing central venous catheters. Technology appraisal guidance TA49. London: NICE; 2002.
  4. Buetti N, Marschall J, Drees M, et al. Strategies to prevent central line-associated bloodstream infections in acute-care hospitals: 2022 update. Infect Control Hosp Epidemiol. 2022;43(5):553–569.
  5. O’Grady NP, Alexander M, Burns LA, et al. Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis. 2011;52(9):e162–e193 (and subsequent Centers for Disease Control and Prevention updates).
  6. Infusion Nurses Society. Infusion Therapy Standards of Practice. 9th ed. J Infus Nurs. 2024;47(1S):S1–S285.
  7. Practice Guidelines for Central Venous Access 2020: An Updated Report by the American Society of Anesthesiologists Task Force on Central Venous Access. Anesthesiology. 2020;132(1):8–43.
  8. Lamperti M, Bodenham AR, Pittiruti M, et al. International evidence-based recommendations on ultrasound-guided vascular access. Intensive Care Med. 2012;38(7):1105–1117.
  9. Parienti JJ, Mongardon N, Mégarbane B, et al. Intravascular complications of central venous catheterization by insertion site (3SITES). N Engl J Med. 2015;373(13):1220–1229.
  10. Pronovost P, Needham D, Berenholtz S, et al. An intervention to decrease catheter-related bloodstream infections in the ICU. N Engl J Med. 2006;355(26):2725–2732.
  11. Berenholtz SM, Pronovost PJ, Lipsett PA, et al. Eliminating catheter-related bloodstream infections in the intensive care unit. Crit Care Med. 2004;32(10):2014–2020.
  12. Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization. Cochrane Database Syst Rev. 2015;(1):CD006962.
  13. Karakitsos D, Labropoulos N, De Groot E, et al. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care. 2006;10(6):R162.
  14. Rupp SM, Apfelbaum JL, Blitt C, et al. Complications of central venous catheterisation and the evidence for ultrasound guidance — reviewed within the American Society of Anesthesiologists central venous access guideline development.
  15. Owen VS, Rosgen BK, Cherak SJ, et al. Adverse events associated with administration of vasopressor medications through a peripheral intravenous catheter: a systematic review and meta-analysis. Crit Care. 2021;25(1):146.
  16. Cardenas-Garcia J, Schaub KF, Belchikov YG, et al. Safety of peripheral intravenous administration of vasoactive medication. J Hosp Med. 2015;10(9):581–585.
  17. Evans L, Rhodes A, Alhazzani W, et al. Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021. Crit Care Med. 2021;49(11):e1063–e1143.
  18. Royal College of Emergency Medicine. Safety and best practice guidance relevant to invasive procedures, ultrasound in emergency medicine, and never events in the emergency department. London: RCEM.

A2Attachment 2: Site Selection, Contraindications, and the Alternatives to a Central Line

The first decision is whether a central venous catheter is needed at all. Table 1 sets out what already does the job, and in most emergencies does it faster. The second decision is the site, and the trade-offs are set out in Table 4. The third is whether anything about this patient changes the site rather than cancelling the procedure (Table 3).

Two principles govern all three: a central venous catheter is never a prerequisite for starting a vasopressor, and a femoral line placed to save time in a resuscitation is a correct decision that can be revised later.

Table 1: What a central venous catheter is for, and what already does the job better — the honest starting position
AccessTime to establishWhat it deliversWhere it is the right answer, and its limits
Large-bore peripheral cannula (14G or 16G)Seconds to a few minutesThe highest flow rate of any access in the department: approximately 180–270 mL/minute by gravity for a short 16G to 14G cannulaThe resuscitation line. Two of these, sited in large proximal veins, out-perform any multi-lumen central catheter for volume. Blood, crystalloid, almost every emergency drug, and a bridging vasopressor all run through them
Ultrasound-guided peripheral cannula in a deep upper-arm vein (basilic, brachial, cephalic)2–10 minutes in trained handsA 20G to 16G cannula, 45–65 mm long, in a vein that cannot be seen or feltThe answer to most "difficult access" that is otherwise escalated to a central line. It requires a long cannula, because a short one placed in a deep vein will fall out of it. Not for a vesicant or for a concentrated vasopressor preparation
Intraosseous needle (proximal humerus preferred, then proximal tibia)Under 60 secondsApproximately 80–150 mL/minute at the humerus under a pressure bag; every resuscitation drug, including vasopressors, blood and contrastThe emergency answer when peripheral access fails. Reaches the central circulation within seconds. Painful in the conscious patient — give 2% preservative-free lidocaine through the needle first. A bridge, not a destination: replace within 24 hours
Midline catheter10–20 minutesA 8–20 cm catheter with its tip in the axillary vein, below the axillaA ward and observation-unit device for several days of non-irritant therapy. It is not a central line, does not take a vasopressor or vesicant, and has no place in the initial resuscitation
Peripherally inserted central catheter (PICC)30–60 minutes, usually a vascular access serviceTrue central tip position through an arm veinFor planned medium-term therapy after the ED phase. Higher thrombosis rate than a short-term central catheter; slow to place; not an emergency device
Central venous catheter (multi-lumen, 7 Fr, 16–20 cm)10–25 minutes including preparation, asepsis and confirmationApproximately 50–60 mL/minute through the widest (distal) lumen — slower than a 16G peripheral cannula, because the lumen is long and narrowConcentrated and vesicant infusions, multiple incompatible infusions, central pressure and saturation measurement, and reliable long-stay access. It is a poor resuscitation line for volume. If volume is the problem, the answer is a short wide cannula or an introducer sheath, not a triple lumen
Large-bore central introducer or dialysis catheter (8.5 Fr or larger)10–25 minutesApproximately 200–250 mL/minute or more; permits rapid transfusion and renal replacementMassive transfusion (EMORBIT-CP-27), renal replacement therapy and transvenous pacing. This — not a triple lumen — is the central catheter to choose when flow is the reason for the line

Approximate flow figures are laboratory and manufacturer values for gravity flow and are given to make one point only: a multi-lumen central venous catheter is chosen for what can be infused through it and for what can be measured from it, and almost never for speed of volume replacement. All figures shall be verified locally against the devices actually stocked before use.

Table 4: Site selection — the trade-offs, stated plainly
FactorRight internal jugular veinSubclavian / infraclavicular axillary veinFemoral vein
Default role in the EDThe default site for a planned ED insertion in a cooperative patient who can lie flatThe site with the lowest infection and the lowest symptomatic thrombosis rate, but the highest pneumothorax rate and the one site that cannot be compressedEntirely acceptable in a resuscitation, in cardiac arrest, in coagulopathy, in respiratory distress, and where the chest or neck is unavailable
Catheter-related bloodstream infectionIntermediateLowestHistorically described as the highest. 3SITES (2015) found no significant difference between femoral and jugular for the combined infection and thrombosis endpoint when the insertion bundle was followed. The site matters far less than the asepsis
Symptomatic deep vein thrombosisIntermediateLowestHighest. Relevant to a line that will stay in for days, much less relevant to one that will be removed or re-sited within 24 to 48 hours
Mechanical complicationLow with ultrasound. Carotid puncture is the main hazard; the dome of the pleura is close at the base of the neckHighest pneumothorax rate. The pleura lies immediately beneath the puncture. Haemothorax and subclavian artery puncture are the other hazardsLowest mechanical risk. No pneumothorax risk. Femoral artery puncture and retroperitoneal haematoma with a high puncture are the hazards
Compressibility if the artery is puncturedCompressible against the transverse processes and the tracheaNOT COMPRESSIBLE. An arterial injury here bleeds into the chest and cannot be pressed. This is why the subclavian is the wrong site in coagulopathyReadily compressible against the femoral head, provided the puncture is below the inguinal ligament
Ultrasound guidanceExcellent — the vein is superficial, large and easily seen in both short and long axis. The reference site for teachingAchievable at the infraclavicular axillary vein, which is the ultrasound-visible continuation of the subclavian; the subclavian proper is obscured by the clavicle. Requires more skillExcellent — superficial, large, easily seen
Position requiredSupine, 10–15° Trendelenburg to distend the vein and reduce air embolism risk; head turned slightly away, not fully rotatedSupine, 10–15° Trendelenburg, arm at the side, a small roll between the scapulae if neededSupine, leg slightly abducted and externally rotated; reverse Trendelenburg (head up) distends the vein. The patient does not have to lie head-down, which is often decisive
Access during resuscitationCompetes with the airway operator for the head endCompetes with chest compressions and defibrillation padsAway from the airway and the chest — it can be done during ongoing CPR
Tip confirmationChest radiograph requiredChest radiograph requiredChest radiograph not required for tip position; confirm free aspiration and flush, and consider abdominal imaging only if malposition is suspected
Comfort, dressing and soilingAwkward dressing; the patient cannot easily turn the headThe most comfortable and the easiest to keep clean and dressedLimits mobility; at risk of soiling in incontinence or diarrhoea; harder to keep an intact dressing

The right internal jugular vein is preferred over the left for a first attempt: it gives a straighter course to the superior vena cava, and the thoracic duct is on the left. Where a line is placed femorally to save time in a resuscitation, that is a correct decision and not a compromise — the line is re-sited electively once the patient is stable, and the reason for the femoral choice is documented. The dominant determinant of catheter-related bloodstream infection is the asepsis of the insertion and the care of the line afterwards, not the anatomical site.

Table 3: Contraindications, and the conditions that change the site rather than cancel the procedure
ConditionEffect on the decisionWhat to do
ABSOLUTE — for that site, not for central access as a whole
Infection, cellulitis or burn at the proposed puncture siteAbsolute contraindication to that siteChoose another site. This does not mean the patient cannot have a central line
Known thrombosis or occlusion of the target veinAbsolute contraindication to that veinChoose another vein. Scan the vein before you prepare the field: an incompressible, echogenic or non-distensible vein on ultrasound is a thrombosed vein, and this finding is one of the most valuable things pre-procedure ultrasound gives you
Patient refusal in a patient with capacityAbsoluteDocument the discussion, the alternatives offered and the decision
Vascular injury or disruption proximal to the site (for example superior vena cava obstruction, a traumatised or ligated vessel, a prior vascular procedure)Absolute for that territoryUse a site that drains into an intact vein. In suspected superior vena cava obstruction or upper-torso venous injury, use the femoral route
RELATIVE — they change the site, the operator, or the timing
Coagulopathy (INR above 1.5, prolonged activated partial thromboplastin time, therapeutic anticoagulation, liver failure, disseminated intravascular coagulation)Relative. It increases bleeding risk and makes an inadvertent arterial puncture much more dangerous. It does not prohibit insertion in a patient who needs oneUse a compressible site — internal jugular or femoral, never the subclavian, which cannot be compressed. Use ultrasound. Use the most experienced available operator. Correct the coagulopathy where time permits and the correction is itself indicated (EMORBIT-CP-25). Consider a smaller catheter
ThrombocytopeniaRelative. A platelet count above 50 × 10⁹/L is the conventional target for a planned insertion; the evidence supports safe ultrasound-guided insertion at substantially lower counts, and an emergency insertion is not deferred for a platelet countCompressible site, ultrasound, experienced operator, smallest adequate catheter. Where platelets are transfused, this follows the local transfusion policy and shall not delay a genuinely time-critical line
Contralateral pneumothorax, contralateral pneumonectomy, or severe unilateral lung diseaseRelative, and one of the most important in the department: a pneumothorax on the remaining good side can be fatalNever puncture the side opposite to an existing pneumothorax, chest drain or pneumonectomy. Either use the same side as the existing pathology (a second pneumothorax on a side already drained is survivable), or use the femoral route, which carries no pneumothorax risk at all
Severe respiratory distress, inability to lie flat, agitation or an uncooperative patientRelative, and frequently decisiveTreat the distress first. Consider the femoral route, which does not require head-down positioning. Consider whether the line is needed at all at this moment, or whether sedation and airway control should come first
Anticipated need for long-term haemodialysis access (chronic kidney disease stage 4 or 5, existing or planned fistula or graft)Relative but strongly directivePreserve the subclavian veins — subclavian stenosis destroys the arteriovenous access of the ipsilateral arm. Avoid the arm veins of the planned fistula side for peripheral access as well. Discuss with nephrology where an urgent dialysis catheter is required
Anatomical distortion: neck or chest trauma, burns, previous surgery or radiotherapy, a large goitre, morbid obesity, a short neckRelativeUltrasound is mandatory, not optional. A different site is often easier than a heroic attempt at a distorted one
Existing intracardiac device leads, or a permanent pacemaker on that sideRelativeAvoid the ipsilateral subclavian; ultrasound-guided internal jugular or femoral is preferred
Raised intracranial pressureRelative, for the internal jugular route and for head-down positioningInternal jugular cannulation and Trendelenburg both raise intracranial pressure. The femoral route avoids both
Cardiac arrest or a peri-arrest patientRelative to the site, not to the procedureDo not interrupt chest compressions to insert a line. Use the femoral route, which is away from the airway and the chest and can be performed during compressions; or use intraosseous access, which is faster (EMORBIT-CP-03)

Correcting a coagulopathy, obtaining a platelet count, or waiting for a calmer moment are all reasonable where the line is not time-critical. Where the line is time-critical, the correct response to a relative contraindication is to change the site, use ultrasound and ask a more experienced operator — not to abandon the patient and not to proceed blind.

A3Attachment 3: Central Venous Catheter Insertion Bundle Checklist and Insertion Record

This checklist shall be held and read aloud by a named team member — normally the procedural nurse — who is empowered by this guideline and by the head of department to stop the procedure at any point if an element is omitted or a break in asepsis occurs. The operator shall stop, correct and resume.

The completed record shall be filed in the medical record and a copy retained by the ED quality team for audit against the performance indicators in section 11.

Part A — Before the field is opened
✓Item
☐The indication is written in the record, in the operator's own words, and states why peripheral and intraosseous access will not serve.
☐Alternatives considered and recorded: large-bore peripheral cannula, ultrasound-guided deep arm cannula, intraosseous needle.
☐Any vasopressor required is already running peripherally — the procedure has not delayed it.
☐Consent obtained and documented, or treatment in the patient's best interests with the reason recorded.
☐Allergies checked — chlorhexidine, iodine, latex, local anaesthetic.
☐Platelet count and international normalised ratio reviewed, or the reason they were not.
☐Contraindications reviewed: site infection, known thrombosis, contralateral pneumothorax or pneumonectomy, anticipated dialysis access, coagulopathy.
☐Both sides pre-scanned: patency, size, depth, compressibility, thrombus, position of the artery. Site and side chosen and stated aloud.
☐Operator credentialled for the procedure and the site, or directly supervised. A dedicated assistant is present.
☐Continuous electrocardiogram, oxygen saturation and blood pressure monitoring in place; resuscitation equipment available.
☐Equipment checked: correct kit, correct length, full-length sterile drape, sterile probe cover and gel, chlorhexidine applicators, local anaesthetic, flushes, caps, dressing, sharps container within reach.
☐Patient positioned: 10–15° Trendelenburg for jugular or subclavian; reverse Trendelenburg with the leg abducted for femoral; left lateral tilt in pregnancy.
☐Plan stated aloud: intended site, catheter, expected depth, and the plan if the first attempt fails.
Part B — The insertion bundle, in order
✓Element
☐Hand hygiene performed immediately before donning sterile attire.
☐Cap, mask, sterile gown and sterile gloves for everyone scrubbed.
☐2% chlorhexidine in 70% alcohol applied with friction for 30 seconds over a wide area.
☐THE ANTISEPTIC WAS ALLOWED TO DRY COMPLETELY BEFORE PUNCTURE — at least 30 seconds on the neck or chest, at least 2 minutes on the groin. It was not fanned, blotted or wiped.
☐Full-length sterile drape applied, head to toe, with a fenestration at the site.
☐Kit prepared on the field: every lumen flushed, wire runs freely, catheter length checked against the intended depth.
☐Local anaesthetic infiltrated and given time to work.
☐Real-time ultrasound guidance used for the puncture, with the needle tip visualised throughout. Dark, non-pulsatile blood aspirated.
☐Guidewire passed without force, insertion limited to approximately 15–20 cm, monitor watched for ectopy.
☐THE GUIDEWIRE WAS VISUALISED INSIDE THE VEIN, IN LONG AXIS WHERE POSSIBLE, AND THE ARTERY CONFIRMED EMPTY OF WIRE, BEFORE THE DILATOR TOUCHED THE SKIN.
☐Skin nicked; dilated only to the depth required, over a wire held and moving freely.
☐Catheter railroaded; guidewire removed complete, shown intact to the assistant, and stated aloud.
☐Every lumen aspirated and flushed; every lumen capped or connected and labelled.
☐Sterile transparent dressing and securement applied; depth at the skin recorded.
☐Sharps disposed of by the operator. Wire, needle and instrument count correct.
☐Number of skin punctures: ________ Number of attempts: ________ Operator changed after three attempts: Yes / No / Not applicable.
Part C — Confirmation and record
✓Item
☐Site and side: ____________________ Catheter type and size: ____________________ Lumens: ______ Length: ______ cm Depth at skin: ______ cm.
☐Date and time of insertion: ____________________ Operator and grade: ____________________ Supervisor: ____________________.
☐Checklist held and read aloud by: ____________________ Procedure halted at any point: Yes / No — if yes, why: ____________________.
☐Catheter confirmed venous — free aspiration and flush of every lumen, and (where there was any doubt) transduced venous waveform or ultrasound visualisation. A blood gas alone was not relied upon.
☐Confirmatory chest radiograph requested for a jugular, subclavian or axillary line — time requested: ________ time performed: ________ reported tip position: ____________________.
☐Bedside lung ultrasound performed after an upper-body insertion: Yes / No / Not applicable. Findings: ____________________.
☐Tip position acceptable (lower third of the superior vena cava at or just above the cavoatrial junction), or the malposition and the action taken recorded: ____________________.
☐Complications: none / arterial puncture / arterial dilation (catheter LEFT IN SITU, vascular surgery called) / pneumothorax / air embolism / arrhythmia / haematoma / retained guidewire (never event — reported) / other: ____________________.
☐THE FULL ASEPTIC BUNDLE WAS COMPLETED: YES / NO. If NO — the omission is recorded in the notes, and this catheter shall be removed or replaced at a new site by: ____________________ (date and time, not later than 48 hours from insertion). Handover to the receiving team acknowledged by: ____________________.
☐Necessity review handed over. What is running through which lumen recorded. Incident report submitted where required.

Completed by: ______________________ Grade: ____________ Date and time: ____________________

Checklist holder: ______________________ Grade: ____________ Signature: ____________________

A copy of this record shall be filed in the medical record and a copy retained by the ED quality team for audit against the performance indicators in section 11.

A4Attachment 4: Complication Recognition, Immediate Management, and Removal

Three of these complications are time-critical and are frequently mishandled at the moment they are discovered. A catheter that has been dilated into an artery shall NOT be removed — leave it clamped in situ and call vascular surgery and interventional radiology. A suspected air embolism is treated by occluding the hub and placing the patient head-down in the left lateral decubitus position with 100% oxygen. A guidewire that is not accounted for is a never event and requires immediate imaging and retrieval, not a further attempt to find it by feel.

Removal is a procedure in its own right, and late air embolism after a central line is removed with the patient sitting up, or with the dressing taken off too early, is a recognised and entirely preventable cause of death.

Table 7: Complications — recognition and immediate management
ComplicationRecognitionImmediate management
Arterial puncture (needle only)Pulsatile bright red flow; ultrasound shows the needle in the artery; a transduced arterial waveformWithdraw the needle. Apply firm continuous direct pressure for at least 10 minutes (longer if coagulopathic or anticoagulated), then re-examine. Observe for an expanding haematoma, airway compromise in the neck, and distal ischaemia. Reassess before any further attempt, and consider a different site and a more experienced operator. Document it
Arterial dilation or cannulation (dilator or catheter in the artery)Pulsatile flow from the catheter; bright red blood; a transduced arterial waveform; an unexpectedly high oxygen saturation on a sample; a catheter seen crossing an artery on imaging. This may only become apparent after the procedure — a high index of suspicion is required in any difficult insertionDO NOT REMOVE THE CATHETER. Removing it converts a controlled injury into uncontrollable bleeding into the chest, neck or retroperitoneum, and is the mechanism by which this complication kills. Leave the catheter in situ and clamped. Call vascular surgery and interventional radiology immediately, and inform the anaesthetic and critical care teams. Removal is performed with surgical or endovascular control of the vessel. Keep the patient in the resuscitation area, group and save, and monitor continuously. Report as a serious incident
PneumothoraxDyspnoea, hypoxaemia, pleuritic pain, reduced air entry, surgical emphysema, rising airway pressures in a ventilated patient, or an abnormal post-procedure radiograph. May be delayed by several hoursImmediate bedside lung ultrasound (absent lung sliding, a lung point) is faster and more sensitive than a supine chest radiograph. Tension pneumothorax: immediate decompression before any imaging. Otherwise, intercostal drain or observation depending on size, symptoms and whether positive-pressure ventilation is required. Do not attempt the contralateral side
Air embolismSudden dyspnoea, hypoxaemia, hypotension, chest pain, altered consciousness or cardiovascular collapse during insertion, during a disconnection, or on removal. A "mill-wheel" murmur is described and is rarely heardImmediately occlude the hub or the open lumen. Place the patient head-down in the left lateral decubitus position (Durant manoeuvre) to trap air at the apex of the right ventricle. Give 100% oxygen. Where a central catheter is in place, attempt aspiration of air from the distal lumen. Resuscitate as required; call critical care. Hyperbaric oxygen may be considered for cerebral arterial gas embolism after senior discussion
Guidewire-induced arrhythmiaVentricular ectopy, ventricular tachycardia or bradycardia appearing as the wire is advancedWithdraw the wire a few centimetres — the arrhythmia almost always stops immediately. Limit wire insertion to approximately 15–20 cm. Continuous electrocardiographic monitoring is mandatory throughout the procedure. Treat a sustained arrhythmia under EMORBIT-CP-03
HaematomaSwelling, bruising or expansion at the site; in the neck, hoarseness, stridor, dysphagia or tracheal deviationDirect pressure. A neck haematoma is an airway emergency: call for senior airway and anaesthetic help early, sit the patient up unless contraindicated, prepare for a difficult airway, and do not wait for stridor. Check coagulation and reverse anticoagulation where indicated (EMORBIT-CP-25)
Retained, sheared or lost guidewireThe wire is not accounted for at the end of the procedure. The wire shall be held at all times and shall be physically shown, intact, to the assistant and counted before the drapes come offThis is a NEVER EVENT. Do not manipulate further. Obtain immediate imaging to locate the wire or fragment, call interventional radiology or cardiology for retrieval, keep the patient monitored, inform the patient and family under the duty of candour, and report immediately through the local incident reporting system with a departmental review
Catheter malpositionThe catheter tip is not in the lower superior vena cava on the confirmatory radiograph — it may be in the contralateral subclavian, the internal jugular, the azygos vein, the right atrium or ventricle, or loopedDo not use a malpositioned catheter for a concentrated vasopressor or a vesicant. Withdraw to the correct depth where the malposition is simple over-insertion. Where the tip is in the wrong vessel, the catheter shall be removed or repositioned under imaging; it shall not be advanced further from outside the sterile field. Repeat the radiograph after any adjustment and document it
Catheter-related bloodstream infectionNew fever, rigors (classically on flushing the line), sepsis without another source, or purulence, tenderness or erythema at the exit site, in a patient with a central catheterTake paired blood cultures — one set through the catheter and one set peripherally, labelled with site and time (EMORBIT-CP-11). Remove the catheter where there is septic shock, purulence or a tunnel infection, or where no other source is found, and send the tip for culture. Start empirical antibiotics per the ED antimicrobial stewardship protocol and the local antibiogram
Catheter-related thrombosisLimb, neck or facial swelling; a distended collateral venous pattern; pain; a catheter that will not aspirateUltrasound with compression. Discuss anticoagulation with the admitting team; catheter removal is usually indicated where the line is no longer needed, and is not by itself an emergency in the ED
Cardiac tamponade from catheter tip perforationSudden hypotension, distended neck veins, muffled heart sounds, electrical alternans, in a patient with a recently placed catheter whose tip was deep or against a wallRare but rapidly fatal. Bedside echocardiography; do not remove the catheter — aspirate from it, and perform urgent pericardiocentesis; call cardiothoracic surgery. Prevented by correct tip position (section 4.3.6)

Every complication shall be documented in the insertion record and reported through the local incident reporting system. Arterial dilation or cannulation, retained guidewire, tamponade, air embolism and any death or serious harm are reportable as serious incidents and shall be reviewed at the departmental morbidity and mortality meeting.

Table 8: Removal — indications and the technique that prevents air embolism
StepWhat to do
INDICATIONS FOR REMOVAL
The line is no longer neededThe commonest and most important indication. Asked at every handover from the moment of insertion
Inserted without full asepsisRemove and, if still required, replace at a new site under full asepsis as soon as the patient is stable and within 48 hours. Guidewire exchange at the same site does not correct a contaminated insertion
Suspected catheter-related bloodstream infectionRemove where there is septic shock, purulence at the exit site, a tunnel infection, or no other source found. Send the tip for culture with paired blood cultures already taken
Mechanical failure, malposition or catheter-related thrombosis with limb compromiseRemove or re-site as clinically indicated
REMOVAL TECHNIQUE — UPPER BODY LINES
PositionLay the patient flat, or 10–15° head-down. Never remove a jugular or subclavian catheter with the patient sitting up: the exit site is then above the level of the right atrium and air is drawn in
BreathingAsk the patient to take a breath in, hold it and bear down (Valsalva) — or, if ventilated, remove at end-inspiration — and withdraw the catheter during that manoeuvre, smoothly and without force
Sealing the tractApply immediate digital pressure for at least 5 minutes (longer if coagulopathic), then an air-occlusive dressing — a sterile gauze with an occlusive film, or a petroleum-based dressing — which stays in place for at least 24 hours. The tract does not seal instantly, and late air embolism occurs after the dressing is removed too early
AfterwardsKeep the patient flat or supine for 30 minutes. Inspect the catheter and confirm it is intact and complete against its stated length; a missing segment is an emergency requiring imaging and retrieval. Document removal, the reason, the integrity of the catheter and any specimen sent
ResistanceNever pull against resistance. Stop, reposition the limb or the patient, apply a warm compress, and seek senior or interventional advice — a catheter may be adherent, knotted or entrapped
Educational use. EM Orbit Suggested Clinical Protocol — written from the published evidence and our clinical opinion. It is for education and guidance only, has not been adopted by any institution, and does not replace your clinical judgement, your local protocols, or official national guidelines.