EMOrbitEmergency medicine, in one orbit Open in the app

Salter-Harris Classification

Paediatric physeal (growth plate) fracture · interactive in the app

Open in the appFree, works on your phone and offline, with every tool alongside.

Criteria

  1. Which pattern is on the film?
    • Type I — through the physis only
    • Type II — physis + metaphysis
    • Type III — physis + epiphysis, into the joint
    • Type IV — epiphysis, physis and metaphysis
    • Type V — crush injury of the physis

The mnemonic is SALTR: Slipped, Above, Lower, Through, Rammed.

The evidence

Derived. Salter RB and Harris WR described the classification from a clinical case series of physeal (growth plate) fracture patterns in children, published in the Journal of Bone and Joint Surgery (American) in 1963; it is an anatomic/descriptive classification of injury to the epiphyseal plate rather than a statistically derived predictive rule, so there is no sample size or diagnostic performance statistic comparable to the other scores in this set.

Validated. As a descriptive anatomic classification rather than a prediction rule, it has not been "validated" in the sensitivity/specificity sense; subsequent literature has instead examined interobserver reliability of radiographic classification, which is only moderate, and proposed expansions (e.g., the Ogden classification, adding types VI-IX) to capture patterns the original five types do not cleanly describe. Could not confirm a single headline reliability statistic that is broadly agreed upon across studies.

Use. Applies to children and adolescents with open growth plates who sustain a fracture near a joint; it is not applicable once the physis has fused (skeletal maturity) and is a radiographic/clinical classification tool rather than an age- or mechanism-restricted decision rule.

Caveats. Type V injuries are notoriously difficult to diagnose acutely because initial imaging often looks normal, so clinicians must maintain a high index of suspicion based on mechanism (axial load/crush) even without positive imaging. Interobserver agreement on distinguishing types (especially I vs II, or III vs IV) is imperfect, and some fracture patterns do not fit neatly into the original five types, which is why expanded classifications (Ogden, Peterson) are sometimes used in the orthopedic literature.

Educational use. Educational use. EM Orbit content supports learning and guideline familiarity. It does not replace your local protocols, senior advice or clinical judgement; follow your institution's official guidance for patient care.