qSOFA

Sepsis — bedside screen, no bloods needed · interactive in the app

Open in the appFree, works on your phone and offline, with every tool alongside.

Criteria

  1. Respiratory rate 22 or more
    • No
    • Yes
  2. Altered mentation — GCS under 15
    • No
    • Yes
  3. Systolic blood pressure 100 mmHg or less
    • No
    • Yes

A screening tool, not a diagnosis. It is deliberately crude so it works at the bedside with no tests.

The evidence

Derived. Seymour CW, Liu VX, Iwashyna TJ, et al. Assessment of Clinical Criteria for Sepsis: For the Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3). JAMA. 2016;315(8):762-774. This study analyzed more than 148,000 encounters with suspected infection across derivation and validation electronic health record cohorts to derive a simple three-item bedside prompt (respiratory rate 22/min or higher, systolic BP 100 mmHg or lower, altered mentation) intended to flag patients outside the ICU at risk of a poor sepsis-related outcome.

Validated. In the same Seymour 2016 study, qSOFA had an AUROC of 0.81 for in-hospital mortality among non-ICU encounters with suspected infection, outperforming SIRS (0.76) and full SOFA (0.79) in that setting, and a qSOFA of 2 or more was associated with a 3- to 14-fold increase in hospital mortality relative to a qSOFA under 2 across risk deciles; however, later pooled external validations found substantially lower sensitivity in unselected ED populations, leading the 2021 Surviving Sepsis Campaign guideline to issue a strong recommendation against using qSOFA alone as the single screening tool for sepsis or septic shock, compared with SIRS, NEWS, or MEWS.

Use. Intended as a rapid bedside prompt for adults with suspected infection outside the ICU (emergency department or general wards) to flag those at higher risk of a poor outcome; it was not derived or validated for use inside the ICU, where full SOFA performed better, and should not be used as the sole tool to rule out sepsis.

Caveats. qSOFA has poor sensitivity as a stand-alone sepsis screen, and the 2021 Surviving Sepsis Campaign guidelines strongly recommend against using it alone rather than SIRS, NEWS, or MEWS for initial screening; a low qSOFA should never be used to defer investigation or treatment of suspected infection, since most patients who go on to deteriorate do not meet the qSOFA threshold early in their course.

Educational use. Educational use. EM Orbit content supports learning and guideline familiarity. It does not replace your local protocols, senior advice or clinical judgement; follow your institution's official guidance for patient care.