Arterial cannulation
Placement of a radial (or femoral) arterial catheter for continuous invasive blood pressure monitoring and repeated arterial blood sampling.
Open in the appFree, works on your phone and offline, with every tool alongside.
Do not forget
- Before Remove every air bubble from the transducer line before connection.
- During Never force the guidewire against resistance.
- After Never inject drugs or infusions into an arterial line.
- After Do not use glucose-containing solutions as the flush fluid.
- After Remove the line immediately if there are signs of distal ischaemia.
Indications
- Continuous beat-to-beat blood pressure monitoring in shock or haemodynamic instability
- Titration of vasopressors, inotropes or intravenous antihypertensives
- Frequent arterial blood gas or blood sampling (e.g. ventilated patient, severe metabolic derangement)
- Failure or unreliability of non-invasive blood pressure measurement (arrhythmia, obesity, burns)
- Post-cardiac arrest care and interfacility transfer of the critically ill patient
Contraindications
Absolute
- Infection, burn or full-thickness injury at the insertion site
- Known absent collateral circulation or critical ischaemia of the limb distal to the site
- Arteriovenous fistula or graft in that limb (dialysis access)
- Raynaud's phenomenon or thromboangiitis obliterans affecting that limb
Relative
- Coagulopathy or anticoagulation (prefer a compressible site such as the radial artery)
- Severe peripheral vascular disease
- Previous surgery or multiple recent punctures at the same artery
- Planned use of the radial artery for coronary angiography or as a surgical conduit (discuss with cardiology)
Equipment
- Personal protective equipment: sterile gloves, apron or gown as per local policy
- 2% chlorhexidine in 70% isopropyl alcohol skin preparation
- Sterile drape and dressing pack
- Arterial cannula: integrated guidewire kit or standard cannula (20 G adult radial)
- Lidocaine 1% with 2–5 mL syringe and 25 G needle
- Ultrasound machine with high-frequency linear probe, sterile sheath and gel
- Pre-primed arterial transducer set with pressure bag and 0.9% sodium chloride flush (heparinised flush only if local protocol)
- Wrist roll or padded board and tape
- Transparent occlusive dressing and red 'ARTERIAL' label
- Suture or securement device
- Sharps bin
Key numbers
- Cannula (adult radial)
- 20 G
- Wrist position
- Dorsiflexion about 30–45°
- Needle angle
- 30–45° to skin
- Pressure bag
- 300 mmHg
- Zero point
- Phlebostatic axis: 4th intercostal space, mid-axillary line
- Lidocaine 1% maximum
- 3 mg/kg plain; 7 mg/kg with adrenaline
Before · Assessment and consent
- Confirm the indication and that invasive monitoring will change management.
- Explain the procedure, risks and benefits; obtain verbal consent if the patient has capacity, otherwise act in best interests and document.
- Check coagulation and platelets if available, and review anticoagulant or antiplatelet therapy.Do not delay insertion in a peri-arrest patient waiting for results.
- Choose the site: non-dominant radial artery first; femoral artery if radial fails or in profound shock; brachial artery only as a last resort.The brachial artery is an end artery with poor collateral supply.
- Assess distal perfusion and collateral flow; a modified Allen's test may be performed but is a poor predictor of ischaemia — ultrasound confirmation of ulnar flow is preferred.
Before · Preparation
- Prime the transducer set with flush, remove all air bubbles and pressurise the bag to 300 mmHg.
- Remove every air bubble from the transducer line before connection.Air in an arterial line can embolise distally or retrogradely to the cerebral circulation, and damps the trace.
- Position the wrist in slight dorsiflexion (about 30–45°) over a roll and tape the hand to a board.
- Scan the artery with the linear probe: confirm a pulsatile, non-compressible vessel and note its depth and course.
- Perform hand hygiene, put on sterile gloves, clean the skin with chlorhexidine and allow it to dry completely; drape the site.
- Infiltrate lidocaine 1% subcutaneously over the artery in the awake patient.Maximum 3 mg/kg plain. Avoid a large bleb that obscures the pulse.
During · Puncture
- Palpate the pulse (or visualise the artery with ultrasound) 1–2 cm proximal to the wrist crease.
- Insert the cannula bevel up at 30–45° to the skin, directed along the line of the artery.
- Advance slowly until a flashback of pulsatile bright red blood appears in the hub.
- If ultrasound-guided, keep the needle tip in view and see it enter the arterial lumen before advancing further.
During · Cannulation
- Integrated guidewire kit: hold the needle still and advance the guidewire smoothly into the artery.
- Never force the guidewire against resistance.Withdraw the wire, reposition and try again; forcing it can dissect or perforate the artery.
- Advance the cannula over the wire (or over the needle), then withdraw the needle and wire together.
- Standard cannula technique: lower the angle after flashback, advance a further 1–2 mm so the cannula tip is in the lumen, then thread the cannula off the needle.
- If flashback is lost, use a transfixion technique only if trained: pass through both walls, withdraw the needle and pull back the cannula slowly until pulsatile flow returns, then advance.
- Press on the artery proximal to the cannula tip to limit bleeding while you connect the line.
- Connect the primed transducer line promptly and flush briefly.
During · Confirmation
- Confirm an arterial waveform on the monitor with a clear upstroke and dicrotic notch.
- Level the transducer to the phlebostatic axis (fourth intercostal space, mid-axillary line) and zero it to atmosphere.
- Perform a fast-flush (square-wave) test to check for over- or under-damping.
- Take an arterial blood gas sample from the port if needed, using the closed sampling system.
After · Securing and labelling
- Secure the cannula with a suture or securement device and a transparent occlusive dressing that leaves the site visible.
- Label the line and the three-way tap clearly as ARTERIAL (red label).
- Never inject drugs or infusions into an arterial line.Intra-arterial injection can cause distal ischaemia, gangrene and limb loss.
- Do not use glucose-containing solutions as the flush fluid.Sampling contamination with glucose can give falsely high results and lead to harmful insulin dosing.
After · Monitoring and documentation
- Check the hand or limb for colour, capillary refill, warmth and pain at regular intervals.
- Remove the line immediately if there are signs of distal ischaemia.Pallor, mottling, coolness, pain or loss of distal pulses.
- Correlate the invasive reading with a non-invasive cuff pressure; re-level and re-zero if the patient's position changes.
- Document the site, cannula size, number of attempts, ultrasound use, waveform confirmation and complications.
- On removal, apply firm pressure for at least 5 minutes (longer if coagulopathic, and longer for the femoral site) and check for haematoma.
Complications
- Haematoma and bleeding
- Arterial thrombosis and distal ischaemia
- Arterial spasm
- Infection (local and catheter-related bloodstream infection)
- Air or thrombus embolism, including retrograde cerebral embolism with vigorous flushing
- Pseudoaneurysm or arteriovenous fistula
- Nerve injury (median nerve at the wrist; femoral nerve at the groin)
- Accidental intra-arterial drug injection
- Disconnection with rapid blood loss
Pitfalls
- Over-extending the wrist flattens and stretches the artery, making cannulation harder.
- Repeated blind passes cause spasm and haematoma — switch early to ultrasound guidance.
- A damped trace underestimates systolic and overestimates diastolic pressure; mean arterial pressure is the most reliable value.
- A transducer left below the phlebostatic axis over-reads; above it under-reads.
- An unlabelled arterial line is a drug-error trap.
In children
Use a 22 G (or smaller) cannula in children and 24 G in neonates; ultrasound guidance is strongly preferred. Use a limited-volume flush system and note flush volumes in infants. Sedation or analgesia is often required.
References
- Association of Anaesthetists guidance on arterial line blood sampling and prevention of hypoglycaemic brain injury (2016)
- NPSA Rapid Response Report: Problems with infusions and sampling from arterial lines (2008)
- Resuscitation Council UK Adult Advanced Life Support Guidelines (2021)
- LITFL Critical Care Compendium — Arterial line insertion (secondary)