Complete heart block — 80, collapsed, rate 32, clammy
EMOD · The Trace 7 of 30
Open in the appFree, works on your phone and offline, with every tool alongside.
THE PATIENT: 80, collapsed, rate 32, clammy · THE DECISION: Atropine, chronotropes, or pacing
The case
An 80-year-old collapsed at home and arrives grey and clammy with a rate of 32. The strip shows P waves marching through at their own rate, QRS complexes at theirs, and no relationship between the two. Nobody is talking to anybody. This is the bradycardia where the sequence of escalation matters, and where the commonest error happens after the pacing starts.
What to look for on the trace
Complete (third-degree) AV block is a diagnosis of dissociation with failure of conduction:
- P waves at one rate, QRS at another, with no fixed PR relationship. Walk the P waves through with calipers: they march regularly, landing before, inside and after QRS complexes indiscriminately. The PR interval, measured naively, changes on every beat — the giveaway that no conduction is occurring.
- The atrial rate is faster than the ventricular rate. This matters: AV dissociation with a ventricular rate faster than the atrial rate (as in an accelerated junctional rhythm) is not complete heart block. In complete block, the atria are trying and failing; the ventricles survive on an escape.
- The escape locates the lesion. A narrow escape at roughly 40–60/min suggests a junctional focus below a nodal block — the more stable variety. A broad escape at roughly 20–40/min suggests a ventricular focus below an infranodal block — slower, less reliable, and more likely to fail into asystole.
- Regularity of the ventricular rhythm. The escape is typically metronomically regular. An irregular slow rhythm should make you reconsider — high-grade (but incomplete) block, or atrial fibrillation with a regularised slow response, which in a digoxin patient is complete block with a junctional escape and spells toxicity.
- Mimics and context: isorhythmic dissociation (rates coincidentally similar — look long enough and the P waves slide through); hyperkalaemia (look for peaked T waves, widened QRS — treat the potassium, not the conduction); inferior infarction (nodal artery territory — block often transient and atropine-responsive); and the drug chart.
The decision
The fork is atropine, chronotropes, or pacing, and the honest answer is all three, in order, without waiting for the previous one to fail completely.
Atropine while you prepare — reasonable, quick, occasionally sufficient in nodal-level block (as after inferior infarction). But understand its limits before you rely on it: it acts on the AV node, and it often fails in infranodal block, where the lesion is below vagal influence. A broad-complex escape predicts atropine failure. Its role here is a bridge and a probe, not a plan.
Then a chronotropic infusion or transcutaneous pacing — whichever is faster to hand, and in a clammy hypotensive 80-year-old that is usually the pads that should already be on the chest. Set a sensible rate, increase the current until capture, and confirm capture properly (below).
Then transvenous pacing and cardiology — transcutaneous pacing is a bridge measured in minutes to hours, not a destination.
The trap once you start pacing is capture. Electrical capture on the monitor is not mechanical capture at the patient. A wide complex after every pacing spike means nothing if there is no pulse and no blood pressure with it — and the monitor can look immaculate while the patient remains in effective asystole. Confirm mechanically: a femoral pulse (the carotid area is corrupted by muscle twitching from the pads), or better, the arterial line trace or ultrasound showing ventricular contraction matching the paced rate. Recheck after every change of current, rate or pad position, and whenever the patient moves.
And give analgesia and sedation. Transcutaneous pacing is genuinely painful — every current delivery contracts the chest wall muscles — and undertreating that is one of the commonest kindnesses we skip. A conscious patient on pacing needs titrated analgesia and usually sedation, with the airway plan that implies.
The traps
- Electrical capture without mechanical capture — treated above because it is the trap. The monitor is not the patient.
- Serial atropine as a strategy. Repeating a drug that acts above a lesion that sits below it, while minutes pass. One or two doses while pads go on; then move.
- Missing the reversible cause. Hyperkalaemia and drug toxicity (beta-blocker, calcium channel blocker, digoxin) produce complete block that pacing handles badly and the antidote handles well. The BRASH spiral — bradycardia, renal failure, AV blockade, shock, hyperkalaemia — is common in exactly this demographic and responds to treating the potassium and the perfusion, not to a pacemaker referral alone.
- Calling every dissociation "complete block". If the ventricular rate exceeds the atrial rate, it is not third-degree block; if occasional early QRS complexes interrupt the regular escape, conduction is intermittently intact (high-grade, not complete). The distinction changes urgency and reversibility.
- Threshold complacency. Pacing thresholds drift — with electrode position, ischaemia, acidosis and time. A patient captured at 60 mA an hour ago may not be captured now. Set the current with a margin above threshold and re-verify.
References
- Resuscitation Council UK, Adult bradycardia algorithm — atropine, second-line options, and transcutaneous pacing.
- ESC Guidelines on cardiac pacing and cardiac resynchronisation therapy — pacing in acquired AV block.
- Farkas J et al. — description of the BRASH syndrome (bradycardia, renal failure, AV blockade, shock, hyperkalaemia).
- LITFL ECG Library — complete heart block; AV dissociation; pacing capture assessment.
3 questions to test yourself on this dose are in the app.
