EMOrbitEmergency medicine, in one orbit Open in the app

10 mmHg —

EMOD · The Number 25 of 30

Open in the appFree, works on your phone and offline, with every tool alongside.

WHAT IT IS: The end-tidal CO2 during CPR below which compressions need attention · IT CHANGES: Whether the team fixes the compressions A low value is information about the resuscitation, not a verdict on the patient.

The case

Six minutes into an arrest, the capnography trace is a flat run of numbers between 6 and 8 mmHg. The team is working hard and the compressions look, to the eye, adequate. Someone says the words that end resuscitations — "the end-tidal is very low" — with the implication hanging in the air. What the number is actually reporting is that the compressions in this room, right now, are not generating enough pulmonary blood flow: the mattress is soft, the compressor has been going for four minutes, and the depth has quietly decayed. It is a message about the technique, not a prognosis about the patient.

Where the number comes from

The physiology is the strongest part of this number's provenance. During CPR, ventilation is relatively fixed and controlled, so exhaled carbon dioxide becomes a function of how much blood the compressions are delivering to the lungs. End-tidal CO2 during arrest is a surrogate for cardiac output. Better compressions move more blood, more CO2 reaches the alveoli, and the trace rises. That relationship is well established in both animal and human work and is the basis for using capnography as a real-time CPR quality monitor.

The specific figure of 10 mmHg is consensus applied to a continuous relationship. The AHA's CPR quality consensus statement and the resuscitation guidelines describe end-tidal CO2 persistently below about 10 mmHg during CPR as a signal that compression quality should be reassessed and improved — depth, rate, recoil, compressor fatigue, hand position, the surface the patient is lying on, and whether ventilation has been excessive. No trial identified 10 as a boundary; it is a round, low value at which "the compressions are probably not doing enough" becomes the most likely explanation.

There is a separate, more contested literature on end-tidal CO2 as a prognostic marker — most often quoted as a persistently low value (again around 10 mmHg) after 20 minutes of advanced life support being associated with very poor outcomes. Those studies are largely observational, predate widespread capnography-guided quality feedback, and include patients whose low values may have reflected poor CPR rather than unsalvageable physiology. Guidelines are consistently careful here: a low end-tidal CO2 should not be used in isolation to terminate resuscitation.

This series uses 10 mmHg as the quality marker, not as a prognostic switch — and the poster carries that framing deliberately.

The edge

It is information about the resuscitation, not a verdict on the patient. A low value should send you to the compressions first. Is the depth adequate — 5–6 cm in an adult, not the 3 cm that fatigue produces? Is the rate 100–120, not the 140 that adrenaline produces? Is the chest fully recoiling, or is the compressor leaning? How long has this person been compressing? Is the patient on a soft mattress that absorbs half of every compression? Fix those and watch the number move — that feedback loop, in real time, is what capnography uniquely offers, and it is worth more than any single reading.

It should not, on its own, end an arrest. Downtime, the cause, temperature, rhythm, reversible pathology and the whole clinical picture belong in that decision. Hypothermic arrest, drowning, pulmonary embolism, local anaesthetic toxicity and arrest in pregnancy all have their own trajectories, and a number that partly reflects the quality of the hands on the chest is a poor arbiter of a life. A department that stops resuscitations on a capnography reading has converted a quality tool into a prognostic one it was never validated as.

Several things distort it in both directions. Adrenaline transiently reduces end-tidal CO2 by increasing pulmonary vascular resistance — a fall shortly after a dose is pharmacology, not deterioration. A leaking, displaced or dislodged airway drops the value abruptly, and the first response to a sudden fall should be to check the airway, not to conclude the patient has deteriorated. Hyperventilation lowers it by blowing off CO2 faster than it is delivered — so the trace can be reporting on the bagging rather than on the compressions. Bronchospasm and severe airflow obstruction distort the waveform shape. In arrest secondary to massive pulmonary embolism, the value can be persistently low despite good compressions, because blood is not reaching the alveoli regardless of flow. Interpret it as a trend, with the context, not as a snapshot.

And the rise is worth stopping for. A sudden, sustained increase — often to values well above the CPR range — is frequently return of spontaneous circulation announcing itself before anyone can feel a pulse. It is the earliest and least invasive indicator available, and it is a legitimate reason to look at the rhythm and the patient mid-cycle, in a series that otherwise argues hard against interrupting compressions (NO. 23).

One thing it does with no ambiguity at all: it confirms tube placement. A sustained capnographic waveform after intubation is the standard for confirming tracheal placement, including during arrest — and its absence in a patient with circulation means the tube is in the wrong place until proven otherwise.

The system it lives in

The number lives inside the CPR quality framework — the AHA consensus statement on CPR quality and the resuscitation council guidelines — alongside compression rate, depth, recoil, compression fraction and minimal interruptions. Waveform capnography is recommended in all intubated arrests, and increasingly in all arrests where an airway allows it, for three jobs at once: confirm the airway, monitor compression quality continuously, and detect return of circulation early.

Applied properly, the system treats capnography as continuous data that reduces the need to stop and look. It also carries explicit limits: values depend on ventilation as well as perfusion; the technology needs a sealed airway to be quantitative, so a leaking supraglottic device or bag-mask ventilation gives less reliable numbers; and thresholds for prognosis are not endorsed as standalone termination criteria in any major guideline.

Termination-of-resuscitation decisions belong to validated rules and local policy, and yours governs — the universal termination-of-resuscitation rules used in prehospital care are built on witnessed status, bystander CPR, shockable rhythm and response to resuscitation, not on a capnography value. The practical departmental question is smaller and answerable: is capnography attached to every arrest as a matter of course, or only when someone reaches for it?

References

  1. Meaney PA, Bobrow BJ, Mancini ME, et al. CPR quality: improving cardiac resuscitation outcomes both inside and outside the hospital. A consensus statement from the American Heart Association. Circulation 2013.
  2. Soar J, Böttiger BW, Carli P, et al. European Resuscitation Council Guidelines: Adult Advanced Life Support. Resuscitation 2021.
  3. Sheak KR, Wiebe DJ, Leary M, et al. Quantitative relationship between end-tidal carbon dioxide and CPR quality during both in-hospital and out-of-hospital cardiac arrest. Resuscitation 2015.
  4. Levine RL, Wayne MA, Miller CC. End-tidal carbon dioxide and outcome of out-of-hospital cardiac arrest. N Engl J Med 1997.
  5. Pokorná M, Necas E, Kratochvíl J, et al. A sudden increase in partial pressure end-tidal carbon dioxide at the moment of return of spontaneous circulation. J Emerg Med 2010.

3 questions to test yourself on this dose are in the app.

Educational use. Educational use. EM Orbit content supports learning and guideline familiarity. It does not replace your local protocols, senior advice or clinical judgement; follow your institution's official guidance for patient care.