WHAT IT IS: The radiographic pneumothorax size separating small from large · IT CHANGES: Observe, aspirate or drain Size guides. Symptoms decide.
The case
A 22-year-old, tall and thin, presents with sudden left-sided pleuritic pain. He walked in, he is talking in full sentences, his saturations are 98% on air, and his heart rate is 78. The radiograph shows a rim of air measured at 2.4 cm at the level of the hilum. In the next bay, a 68-year-old with severe COPD is breathless at rest with a 1.4 cm rim. One measurement is above the traditional line and one below, and the number would send the wrong patient to the drain trolley in both cases.
Where the number comes from
This is one of the more genuinely unstable numbers in the series, and the instability is recent enough that many clinicians are still quoting a superseded version.
The 2 cm figure comes from the British Thoracic Society pleural disease guidelines, which for years defined a large pneumothorax as an interpleural distance of 2 cm or more measured at the level of the hilum on a chest radiograph — a figure chosen partly because a 2 cm rim approximates roughly 50% of hemithorax volume, and partly because it is measurable and reproducible at the bedside. The American College of Chest Physicians consensus statement used a different rule entirely: 3 cm measured from the apex to the cupola. Two guidelines, two measurement points, two thresholds, and a pneumothorax that is comfortably "large" by one definition and "small" by the other.
That divergence was never resolved by evidence, and the direction of travel has since been away from size as the primary determinant. Trials of conservative management — most influentially the Australasian PSP trial (Brown and colleagues, NEJM 2020), which randomised patients with moderate-to-large primary spontaneous pneumothorax to interventional versus conservative management and found conservative care non-inferior for lung re-expansion at eight weeks, with fewer adverse events — undercut the assumption that a large radiographic pneumothorax obliges a procedure. The 2023 BTS pleural disease guideline consequently restructured its approach around symptoms, patient priorities and risk features (including whether the patient is at high risk of an adverse outcome) rather than a single size cut-off, retaining size as one input among several.
So the honest statement: 2 cm is a consensus, measurable, guideline-specific figure that has never had a derivation cohort behind it, and the guideline that produced it has moved on. If your department still runs a 2 cm rule, it is running a defensible older algorithm, not a settled fact.
The edge
Size guides. Symptoms decide. A small pneumothorax in a breathless patient with poor respiratory reserve is a bigger clinical problem than a large one in a well young adult — which is the whole point of the opening case. Underlying lung disease changes the calculation entirely: the distinction between primary spontaneous pneumothorax (no known lung disease) and secondary spontaneous pneumothorax (COPD, fibrosis, cystic fibrosis, malignancy) matters far more than the centimetres, because the secondary patient has no reserve to lose, tolerates the same volume of air far worse, and carries a materially higher mortality. Most guidance therefore treats secondary pneumothorax more aggressively at smaller sizes and admits patients who would be sent home with a primary one.
The measurement itself is soft. A pneumothorax is a three-dimensional collection measured on a two-dimensional projection, and the relationship between a linear rim and a volume is approximate at best. Radiographs are taken supine in trauma and unwell patients, where air layers anteriorly and can be near-invisible; loculated and apical collections defeat a hilar measurement; and inter-observer variation on where exactly to measure is real. A number carried to one decimal place from a measurement this soft is false precision.
Ultrasound has changed detection more than sizing. Point-of-care ultrasound is more sensitive than supine radiography for pneumothorax — absent lung sliding, absent B-lines, the lung point — and it is excellent at answering "is there one?" It is much weaker at "how big?", and the lung point's position gives only a crude indication of extent. CT is the reference standard for size and is often what finally settles a disputed radiograph, but a CT ordered to measure a pneumothorax in a patient whose management is symptom-driven is a scan doing nothing useful.
And the number does not exist at all in tension pneumothorax. Tension is a clinical diagnosis — progressive respiratory distress, haemodynamic compromise, and the physical signs — treated immediately by decompression before anyone measures anything. A patient in extremis does not get a radiograph first, and a size threshold has no role in that decision. Similarly, traumatic pneumothorax, pneumothorax in the ventilated patient, and bilateral disease run on their own logic, where even small collections may need drainage because positive pressure will enlarge them.
Finally, the number does not decide disposition on its own. Whether the patient can return, how far they live from the hospital, whether they will fly or dive, whether they smoke, and whether this is a first or recurrent episode all belong in the conversation — and the modern guidelines make patient priorities an explicit input rather than an afterthought.
The system it lives in
The parent system is the pleural disease guideline your department has adopted, and the honest instruction is to find out which one that is. Historically the BTS algorithm ran: primary or secondary; symptomatic or not; size above or below the 2 cm hilar line; then observe, aspirate, or intercostal drain, with aspiration first-line for many primary pneumothoraces and drainage reserved for failure or for secondary disease. The ACCP algorithm used its 3 cm apex-to-cupola measurement and a different escalation pattern.
The 2023 BTS restructuring reorganises that around three questions: is the patient stable; are there high-risk characteristics; and what does the patient prioritise (rapid resolution, avoidance of a procedure, avoidance of admission)? Options run from conservative management with follow-up, through needle aspiration and ambulatory devices, to standard chest drainage — with size retained as evidence about the pneumothorax rather than as the switch that decides.
Its limits are worth naming. The conservative-management evidence base is strongest in primary spontaneous pneumothorax in young patients with reliable follow-up; extrapolating it to secondary pneumothorax, to patients who cannot return, or to trauma is not supported. Ambulatory devices require a service set up to follow them. And none of this applies to tension, to the ventilated patient, or to haemopneumothorax.
Which guideline your department follows, which measurement point it uses, and what its thresholds are is protocol territory, and yours governs — and a department in which different clinicians are silently using different guidelines will produce inconsistent care on identical films. That is a worthwhile thing to go and check.
References
- MacDuff A, Arnold A, Harvey J; BTS Pleural Disease Guideline Group. Management of spontaneous pneumothorax: British Thoracic Society pleural disease guideline 2010. Thorax 2010.
- Roberts ME, Rahman NM, Maskell NA, et al. British Thoracic Society Guideline for pleural disease. Thorax 2023.
- Baumann MH, Strange C, Heffner JE, et al. Management of spontaneous pneumothorax: an American College of Chest Physicians Delphi consensus statement. Chest 2001.
- Brown SGA, Ball EL, Perrin K, et al. Conservative versus interventional treatment for spontaneous pneumothorax (PSP trial). N Engl J Med 2020.