The curtain — ocular ultrasound — 59, sudden floaters then a curtain across the vision
EMOD · The Image 29 of 30
Open in the appFree, works on your phone and offline, with every tool alongside.
THE PATIENT: 59, sudden floaters then a curtain across the vision · THE QUESTION: The scan almost nobody does
The case
A 59-year-old myope describes a shower of floaters yesterday evening, then flashes of light in the peripheral field, and this morning a shadow coming across the vision from the side — she demonstrates it with her hand, moving inwards. Her visual acuity is reduced in the outer field but the central vision is, for now, intact. There is no ophthalmoscope in the department that anyone is confident with, the on-call ophthalmologist is off-site, and the plan is forming around "refer and see". This is a scan most emergency departments never perform, it takes about ninety seconds, and it can transform the referral conversation.
The sign — how it forms and where to look
The anatomy and physics. The globe is a fluid-filled sphere — an almost ideal acoustic window. The vitreous is anechoic; the retina, choroid and sclera form the bright posterior wall. When the neurosensory retina separates from the underlying retinal pigment epithelium, fluid enters the subretinal space, and the detached retina becomes a discrete membrane suspended within anechoic vitreous — highly visible precisely because it has fluid on both sides.
The sign: a hyperechoic, undulating, sheet-like membrane within the vitreous cavity, moving with eye movement (kinetic echography) but remaining tethered at the optic disc — and, in a total detachment, also at the ora serrata anteriorly, producing the classic funnel or V shape converging on the nerve head. That tethering at the disc is the discriminator, and it is the reason the patient is asked to move the eye during the scan: the membrane sweeps but returns, anchored.
Probe, preset, technique — and the safety rules that govern it.
- High-frequency linear probe (a 7.5–12 MHz or higher small-parts probe), ophthalmic preset if the machine has one.
- Use the ophthalmic preset or reduce the output power. The eye and orbit have the lowest thermal and mechanical index limits of any application, and a machine left on a vascular or musculoskeletal preset delivers far more acoustic energy than ocular scanning requires. If no ophthalmic preset exists, turn the output down and keep the study brief.
- The eyelid stays closed. A generous layer of gel is placed on the closed lid — or a transparent adhesive dressing over the lid with gel on top, which many find cleaner — and the probe floats on the gel with essentially no pressure on the globe.
- Rest the hand on the bony orbital rim, not on the eye, so the probe cannot be pushed down.
- Scan in transverse and sagittal planes, sweeping through the entire globe, then ask the patient to look left, right, up and down while scanning — dynamic assessment is what characterises a membrane and separates the diagnoses.
- Never scan a suspected globe rupture or open globe injury. Pressure on a ruptured globe risks extrusion of intraocular contents. Suspected penetrating injury, a visibly deformed globe, a peaked pupil, prolapsed uveal tissue or a strong mechanism means a shield, no pressure, no probe, and an immediate ophthalmology call.
The differential of a membrane — the reason technique matters:
- Posterior vitreous detachment (PVD): far commoner, and the usual cause of new floaters. The membrane is thinner, more mobile, undulates freely with a lively "after-movement", and is not tethered at the optic disc. Distinguishing PVD from retinal detachment is the main interpretive challenge of this scan, and it is genuinely difficult — a PVD can look convincing, and PVD frequently coexists with, and precedes, a retinal tear.
- Vitreous haemorrhage: swirling low-level echoes filling the vitreous, moving like a snowstorm with eye movement, rather than a discrete sheet. Often requires increased gain to see at all.
- Choroidal detachment: thicker, smoother, more dome-shaped, and typically does not extend to the optic disc — it stops at the vortex vein insertions.
- Retinoschisis, a dense membrane in longstanding disease, and asteroid hyalosis round out the list.
What it changes
It changes the urgency and content of the ophthalmology conversation — which, in a specialty where the emergency clinician often cannot examine the fundus adequately, is a substantial contribution.
The concept driving that urgency is macula-on versus macula-off. While the macula remains attached, central vision is preserved and surgical repair is time-critical — the outcome for central acuity is markedly better if the macula is reattached before it detaches. Once the macula is off, the urgency changes in character, though repair is still required. A patient describing a peripheral curtain with intact central acuity is potentially macula-on, and that is exactly the patient in whom a bedside finding accelerates the referral from "clinic tomorrow" to "speak to the on-call now".
Ocular ultrasound also earns its place because the same ninety-second window answers several other questions:
- Optic nerve sheath diameter, measured 3 mm behind the globe, as a surrogate marker of raised intracranial pressure.
- Lens dislocation or subluxation after trauma.
- Vitreous haemorrhage in a patient with no red reflex.
- Intraocular foreign body.
- Central retinal artery occlusion — the "spot sign" of a visible embolus — and pupillary assessment when the lids are swollen shut.
That breadth is why it is worth learning even for a clinician who expects to use it rarely.
What a negative does not exclude
A normal ocular ultrasound does not exclude retinal pathology. Small, peripheral or shallow detachments and, critically, retinal tears and holes — the lesions that precede detachment and are the whole point of urgent review — are frequently not visible on bedside ultrasound. A patient with flashes, new floaters or a field defect needs ophthalmological examination with indirect ophthalmoscopy and scleral indentation, and a reassuring scan does not substitute for it.
Nor does a normal scan exclude the non-structural causes of acute visual loss: central retinal artery or vein occlusion, optic neuritis, giant cell arteritis, occipital stroke, and acute angle-closure glaucoma all produce sudden visual symptoms with a globe that looks unremarkable on ultrasound. Giant cell arteritis in particular is a clinical and laboratory diagnosis with a treatment window measured in hours for the fellow eye.
And the sign's ambiguity runs the other way too: a membrane seen is not necessarily a retinal detachment, and over-calling a posterior vitreous detachment generates an unnecessary emergency. Bedside ultrasound in this application is operator-dependent, with accuracy improving substantially with training; a clinician who has scanned five eyes should treat their own result as supportive rather than definitive, in either direction.
The traps
- Any pressure on a possibly ruptured globe. The single unforgivable error of this scan. Suspected open globe means shield and refer, not scan.
- Scanning on a non-ophthalmic preset, delivering unnecessary acoustic energy to the eye.
- Calling every membrane a retinal detachment. Tethering at the disc, thickness and mobility separate PVD from detachment, and PVD is far commoner.
- A static examination. Without asking the patient to move the eye, the two membranes look alike.
- Insufficient gain for vitreous haemorrhage, which is easily missed at standard settings.
- Using a normal scan to downgrade the referral. Tears and small peripheral detachments are invisible; the indirect ophthalmoscope is the reference standard.
- Missing the macula question. Asking whether central acuity is preserved costs seconds and is the detail that most changes the urgency.
- Forgetting the non-structural causes — a normal-looking globe with sudden visual loss still needs a differential.
References
- Blaivas M, Theodoro D, Sierzenski PR. A study of bedside ocular ultrasonography in the emergency department. Acad Emerg Med 2002.
- Vrablik ME et al. The diagnostic accuracy of bedside ocular ultrasonography for the diagnosis of retinal detachment: a systematic review and meta-analysis. Ann Emerg Med 2015.
- Kilker BA, Holst JM, Hoffmann B. Bedside ocular ultrasound in the emergency department. Eur J Emerg Med 2014.
- American Academy of Ophthalmology. Preferred Practice Pattern — Posterior Vitreous Detachment, Retinal Breaks, and Lattice Degeneration.
- British and Eire Association of Vitreoretinal Surgeons (BEAVRS) guidance on the urgency of macula-on retinal detachment repair.
- American Institute of Ultrasound in Medicine (AIUM) — ophthalmic output display standards and acoustic output limits.
3 questions to test yourself on this dose are in the app.