EMOrbitEmergency medicine, in one orbit Open in the app

B lines — 74, acutely breathless overnight, wheezing

EMOD · The Image 19 of 30

Open in the appFree, works on your phone and offline, with every tool alongside.

THE PATIENT: 74, acutely breathless overnight, wheezing · THE QUESTION: Cardiogenic, or something else

The case

A 74-year-old wakes at three in the morning unable to breathe, sits on the edge of the bed, and arrives in the department an hour later still fighting for air. There is audible wheeze, and somebody in triage has written "asthma" with a question mark that everyone downstream has read as a full stop. She has ankle swelling she says is "just her age", takes a diuretic she may or may not have been taking, and her chest film is pending. The probe is placed on the chest and multiple vertical lines appear in several zones. What those lines mean depends entirely on their pattern — and on what else the scan shows.

The sign — how it forms and where to look

The physics. Ultrasound is stopped almost completely by air, so normal aerated lung produces only reverberation artefact: horizontal A-lines, repeating at intervals equal to the skin-to-pleura distance, and a shimmering pleural line that slides with respiration. Now thicken the subpleural interlobular septa with fluid. Each thickened septum, surrounded by air-filled alveoli, becomes a tiny acoustic trap — sound enters, reverberates within the fluid-filled structure, and leaks back to the probe over a prolonged period. The result is a B-line: a discrete vertical hyperechoic artefact that

All five features are required. An artefact failing any of them is something else — a comet-tail from a rib or a superficial structure, a Z-line (short, fading, does not erase A-lines, does not move), or noise.

Probe, preset and technique. Either a phased-array (1–5 MHz), curvilinear (2–5 MHz) or linear (5–12 MHz) probe will show B-lines; phased-array and curvilinear probes are preferred for whole-lung surveys because their sector width samples more of each interspace, while a linear probe resolves the pleural line itself best. The technical points that make or break the examination:

Interpretation is about pattern, not presence.

What it changes

The scan changes the treatment pathway in the first ten minutes, which is when it matters in acute breathlessness. Lung ultrasound is considerably more sensitive than the chest radiograph for interstitial oedema and does not require the patient to leave the trolley or wait for a film. A diffuse bilateral B-pattern in this presentation supports acute cardiogenic pulmonary oedema and directs treatment towards preload and afterload reduction and non-invasive ventilation per local protocol, rather than towards escalating bronchodilators for an asthma that was never there. Equally, an A-line pattern with sliding in a wheezing, breathless patient argues against oedema and supports the obstructive diagnosis — which is the more useful direction of information in a patient about to be given a diuretic on a hunch.

The scan is also more than the lungs: combined with a focused cardiac view, an IVC assessment and a look for pleural effusions, it forms the shock or dyspnoea protocol that answers the actual clinical question — not "are there B-lines" but "why can this patient not breathe".

What a negative does not exclude

B-lines are a finding, not a diagnosis, and their absence excludes less than it seems to.

So interpret the pattern, not the presence: bilateral, symmetrical and dependent points one way; focal and irregular points another. And the counterweight from the other series holds — not all wheeze is asthma, and the heart wheezes too.

The traps

References

  1. Lichtenstein D, Mézière G et al. The comet-tail artifact: an ultrasound sign of alveolar-interstitial syndrome. Am J Respir Crit Care Med 1997.
  2. Lichtenstein DA, Mezière GA. Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol. Chest 2008.
  3. Volpicelli G et al. International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med 2012.
  4. Al Deeb M et al. Point-of-care ultrasonography for the diagnosis of acute cardiogenic pulmonary edema in patients presenting with acute dyspnea: systematic review and meta-analysis. Acad Emerg Med 2014.
  5. Pivetta E et al. Lung ultrasound-implemented diagnosis of acute decompensated heart failure in the ED. Chest 2015.
  6. American College of Emergency Physicians. Ultrasound Guidelines — thoracic and lung ultrasound.

3 questions to test yourself on this dose are in the app.

Educational use. Educational use. EM Orbit content supports learning and guideline familiarity. It does not replace your local protocols, senior advice or clinical judgement; follow your institution's official guidance for patient care.