B lines — 74, acutely breathless overnight, wheezing
EMOD · The Image 19 of 30
Open in the appFree, works on your phone and offline, with every tool alongside.
THE PATIENT: 74, acutely breathless overnight, wheezing · THE QUESTION: Cardiogenic, or something else
The case
A 74-year-old wakes at three in the morning unable to breathe, sits on the edge of the bed, and arrives in the department an hour later still fighting for air. There is audible wheeze, and somebody in triage has written "asthma" with a question mark that everyone downstream has read as a full stop. She has ankle swelling she says is "just her age", takes a diuretic she may or may not have been taking, and her chest film is pending. The probe is placed on the chest and multiple vertical lines appear in several zones. What those lines mean depends entirely on their pattern — and on what else the scan shows.
The sign — how it forms and where to look
The physics. Ultrasound is stopped almost completely by air, so normal aerated lung produces only reverberation artefact: horizontal A-lines, repeating at intervals equal to the skin-to-pleura distance, and a shimmering pleural line that slides with respiration. Now thicken the subpleural interlobular septa with fluid. Each thickened septum, surrounded by air-filled alveoli, becomes a tiny acoustic trap — sound enters, reverberates within the fluid-filled structure, and leaks back to the probe over a prolonged period. The result is a B-line: a discrete vertical hyperechoic artefact that
- arises from the pleural line (never from below it),
- is laser-like, narrow and well defined,
- extends to the bottom of the screen without fading,
- erases the A-lines it crosses,
- and moves with lung sliding.
All five features are required. An artefact failing any of them is something else — a comet-tail from a rib or a superficial structure, a Z-line (short, fading, does not erase A-lines, does not move), or noise.
Probe, preset and technique. Either a phased-array (1–5 MHz), curvilinear (2–5 MHz) or linear (5–12 MHz) probe will show B-lines; phased-array and curvilinear probes are preferred for whole-lung surveys because their sector width samples more of each interspace, while a linear probe resolves the pleural line itself best. The technical points that make or break the examination:
- Turn off harmonics, spatial compounding and multibeam processing. These algorithms exist to suppress artefact, and B-lines are artefact — leaving them on erases the finding.
- Depth of about 12–18 cm, so B-lines can be seen reaching the far field; a shallow depth truncates them and makes them indistinguishable from short comet tails.
- Single focal zone set at the pleural line.
- Longitudinal orientation, perpendicular to the ribs, framing the pleural line between two rib shadows — the bat sign — so you are certain you are looking at pleura.
- Scan a defined multi-zone protocol on both sides — commonly four or eight zones per hemithorax (anterior and lateral, superior and inferior), as in the BLUE protocol and the international consensus. A single window is not a lung examination.
- A zone is positive when three or more B-lines are seen in one intercostal space; two or more positive zones bilaterally constitutes a positive interstitial pattern.
Interpretation is about pattern, not presence.
- Bilateral, symmetrical, diffuse B-lines, worse in dependent zones, with a smooth regular pleural line — the pattern of cardiogenic pulmonary oedema. Often with bilateral pleural effusions.
- Focal or asymmetrical B-lines with an irregular, thickened or fragmented pleural line, subpleural consolidations and spared areas — the pattern of pneumonia, contusion, ARDS or infarction.
- A-line pattern with sliding, and no B-lines — argues against interstitial fluid, and in a breathless patient points towards asthma, COPD or pulmonary embolism.
What it changes
The scan changes the treatment pathway in the first ten minutes, which is when it matters in acute breathlessness. Lung ultrasound is considerably more sensitive than the chest radiograph for interstitial oedema and does not require the patient to leave the trolley or wait for a film. A diffuse bilateral B-pattern in this presentation supports acute cardiogenic pulmonary oedema and directs treatment towards preload and afterload reduction and non-invasive ventilation per local protocol, rather than towards escalating bronchodilators for an asthma that was never there. Equally, an A-line pattern with sliding in a wheezing, breathless patient argues against oedema and supports the obstructive diagnosis — which is the more useful direction of information in a patient about to be given a diuretic on a hunch.
The scan is also more than the lungs: combined with a focused cardiac view, an IVC assessment and a look for pleural effusions, it forms the shock or dyspnoea protocol that answers the actual clinical question — not "are there B-lines" but "why can this patient not breathe".
What a negative does not exclude
B-lines are a finding, not a diagnosis, and their absence excludes less than it seems to.
- An A-line pattern does not exclude heart failure. A patient with chronic compensated failure, or one imaged before fluid has accumulated interstitially, can have few B-lines; treatment can also clear them within hours, so a scan after diuresis or non-invasive ventilation may look normal.
- It does not exclude pulmonary embolism, which classically shows an A-line pattern with preserved sliding — indeed that combination in a hypoxic patient should raise, not lower, concern for PE.
- A negative scan of the anterior zones does not exclude posterior pathology. In a supine patient, consolidations and effusions collect posteriorly, and posterolateral windows are the ones most often skipped and most often diagnostic.
- And in the other direction, the presence of B-lines does not confirm heart failure. A few B-lines in the dependent bases can be normal, particularly in older patients; chronic interstitial lung disease produces them permanently, alongside an irregular pleural line and subpleural changes; and renal failure, ARDS, pneumonia and contusion all generate them.
So interpret the pattern, not the presence: bilateral, symmetrical and dependent points one way; focal and irregular points another. And the counterweight from the other series holds — not all wheeze is asthma, and the heart wheezes too.
The traps
- Harmonics and compounding left on, quietly deleting the finding — the single commonest technical cause of a false negative.
- Insufficient depth, so B-lines cannot be distinguished from short comet-tail artefacts.
- Scanning one or two anterior zones and calling it a lung examination; the pattern only emerges across a protocol.
- Calling any vertical line a B-line. Z-lines are common, fade out, and do not erase A-lines — mistaking them for B-lines produces false positives and unnecessary diuresis.
- Ignoring the pleural line's character. Smooth and regular versus thickened and fragmented is what separates cardiogenic oedema from pneumonia and interstitial disease, and it is free information on the same image.
- Forgetting the chronic patient. A patient with pulmonary fibrosis has B-lines on a good day; without the comparison, they are treated for oedema they do not have.
- Scanning only after treatment has begun. B-lines clear with effective therapy, so an early scan carries far more information than a late one.
References
- Lichtenstein D, Mézière G et al. The comet-tail artifact: an ultrasound sign of alveolar-interstitial syndrome. Am J Respir Crit Care Med 1997.
- Lichtenstein DA, Mezière GA. Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol. Chest 2008.
- Volpicelli G et al. International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med 2012.
- Al Deeb M et al. Point-of-care ultrasonography for the diagnosis of acute cardiogenic pulmonary edema in patients presenting with acute dyspnea: systematic review and meta-analysis. Acad Emerg Med 2014.
- Pivetta E et al. Lung ultrasound-implemented diagnosis of acute decompensated heart failure in the ED. Chest 2015.
- American College of Emergency Physicians. Ultrasound Guidelines — thoracic and lung ultrasound.
3 questions to test yourself on this dose are in the app.