EMOrbitEmergency medicine, in one orbit Open in the app

The halo sign — coin versus button battery — 3, witnessed ingestion, now drooling

EMOD · The Image 14 of 30

Open in the appFree, works on your phone and offline, with every tool alongside.

THE PATIENT: 3, witnessed ingestion, now drooling · THE QUESTION: The finding that turns waiting into an emergency

The case

A three-year-old swallowed something an hour ago; his older sister saw it happen and thinks it came from the television remote. He is now drooling, refusing to drink, and pointing at his throat. An AP chest and neck film shows a round metallic density at the level of the thoracic inlet. On the film it is round, dense and metallic — and whether this child waits for a routine list or goes straight to theatre depends on a single detail visible in that shadow.

The sign — how it forms and where to look

Coins and button batteries are both round, both radio-opaque, and both lodge at the same places — the natural narrowings of the oesophagus, most often at the thoracic inlet / cricopharyngeus, then the aortic arch crossing, then the gastro-oesophageal junction. On a plain film they look almost identical, and that resemblance is the entire clinical problem.

The discriminator is structural. A coin is a single homogeneous metal disc: uniformly dense, with a clean, sharp outer edge and nothing inside it. A button battery is two plates crimped together around an insulating gasket, and the assembly has a slightly narrower crimped rim and a thicker central core. Radiographically that construction produces:

Both views are essential. The halo can be subtle, degraded by exposure, obscured by overlying structures, or simply absent on a rotated frontal film — and the lateral step-off is often the more convincing of the two. A single AP film is not enough to call a metallic disc a coin.

Two further reading points. The position matters: an oesophageal disc classically sits en face (coin-on) on the AP and edge-on on the lateral, because the oesophagus is a flattened tube — whereas a tracheal foreign body tends to orient the other way. And magnets are the other disc-shaped emergency: multiple magnets, or a magnet with another metallic object, can pinch bowel wall between them and cause pressure necrosis and perforation, so a "second coin" on the film deserves its own thought.

What it changes

The finding changes the timeline from hours to minutes. An oesophageal button battery is a time-critical emergency requiring immediate endoscopic removal, and the reason is electrochemical rather than mechanical. Once lodged against moist mucosa, the battery completes a circuit through the tissue; hydroxide ions generated at the negative pole produce a liquefactive, alkaline caustic burn in the surrounding mucosa. That injury begins within a couple of hours and continues after the battery is removed, because the alkali persists in the tissue. Injury depth does not require the battery to be "leaking" — an intact, apparently working battery causes it. The consequences of delay are oesophageal perforation, tracheo-oesophageal fistula, mediastinitis, vocal cord palsy, stricture, and — the reason these children can die weeks later — erosion into the aorta with catastrophic haemorrhage.

So: nil by mouth, immediate escalation to the team who will perform endoscopy (ENT, paediatric surgery or gastroenterology per local pathway), and no waiting for the morning list. Mitigation before removal — such as the administration of honey in children above a defined age, described in specialist guidance to buffer the alkali — may be considered only under local guidance and where it will not delay removal; check your own protocol rather than acting from a post.

By contrast, an oesophageal coin is urgent but not the same category: an asymptomatic distal oesophageal coin may be observed for spontaneous passage over a defined window per local protocol, while a symptomatic or proximally lodged coin is removed endoscopically. Objects that have passed the pylorus are usually managed expectantly — except batteries and magnets.

The halo is the only thing separating those two pathways on a plain film, which is why it is worth teaching properly.

What a negative does not exclude

The absence of a visible halo does not exclude a button battery. Small batteries, over-exposed or rotated films, and single-projection imaging all suppress the sign, and radiologically confident coin calls have proven wrong at endoscopy. Where the history suggests a battery — a device from a remote, hearing aid, key fob, toy, or a parent who reports a missing cell — the object is treated as a battery until endoscopy proves otherwise, whatever the film's appearance says.

Two further negatives. A radiolucent foreign body — plastic, food, wood — will not appear at all, so a normal film in a drooling child does not exclude an oesophageal foreign body; persistent drooling, dysphagia or refusal to feed is an indication for direct visualisation. And a normal-appearing film after a witnessed battery ingestion does not exclude injury if the battery has already passed into the stomach: a symptomatic patient, or a large battery in a small child, may still warrant removal and follow-up per specialist guidance.

The traps

References

  1. Litovitz T et al. Emerging battery-ingestion hazard: clinical implications. Pediatrics 2010.
  2. Litovitz T et al. Preventing battery ingestions: an analysis of 8648 cases. Pediatrics 2010.
  3. Jatana KR, Litovitz T, Reilly JS et al. Pediatric button battery injuries: 2013 task force update. Int J Pediatr Otorhinolaryngol 2013.
  4. NASPGHAN / ESPGHAN guidance on the management of ingested foreign bodies in children, including button batteries and magnets.
  5. National Capital Poison Center — button battery ingestion triage guideline (honey and mitigation guidance).
  6. Royal College of Emergency Medicine / RCPCH safety alerts on button battery ingestion.

3 questions to test yourself on this dose are in the app.

Educational use. Educational use. EM Orbit content supports learning and guideline familiarity. It does not replace your local protocols, senior advice or clinical judgement; follow your institution's official guidance for patient care.