The lightbulb sign — 44, seizure, painful shoulder, arm held internally rotated
EMOD · The Image 6 of 30
Open in the appFree, works on your phone and offline, with every tool alongside.
THE PATIENT: 44, seizure, painful shoulder, arm held internally rotated · THE QUESTION: Why a single view is not enough
The case
A 44-year-old has a witnessed generalised seizure. In the recovery phase he complains of a painful right shoulder, held adducted and internally rotated; attempts at external rotation are met with pain and a mechanical block. The AP radiograph is reported as normal — and this is entirely typical, because the diagnosis that follows seizures, electrocutions and direct anterior blows is the one the AP film is structurally bad at showing. Posterior shoulder dislocation is missed at first presentation in a large share of cases, in some published series around half, and the miss is usually not a careless read: it is a read of the wrong projection.
The sign — how it forms and where to look
Anterior dislocation announces itself: the humeral head sits obviously below and medial to the glenoid. Posterior dislocation hides, because the head moves directly backwards, staying at roughly the same height and remaining superimposed on the glenoid in the AP projection. What changes is not position on the film but rotation — the powerful internal rotators (subscapularis, pectoralis major, latissimus) drag the humerus into fixed internal rotation as it dislocates, and it is the rotation that the AP film records.
In internal rotation the greater and lesser tuberosities rotate out of profile, and the humeral head, normally shaped like a walking stick's handle on the AP, becomes symmetrically round — the lightbulb sign. A shoulder that looks like a lightbulb on the AP is internally rotated; an internally rotated shoulder that cannot be externally rotated after a seizure is posteriorly dislocated until proven otherwise.
The supporting signs on the AP:
- The rim sign — widening of the joint space between the anterior glenoid rim and the humeral head beyond about six millimetres.
- Loss of the normal half-moon overlap between the humeral head and the glenoid — the crescent of superimposition disappears or distorts.
- The trough sign — a dense vertical line within the head from an impaction fracture of its anterior surface (the reverse Hill-Sachs lesion) created as it locks on the posterior glenoid rim.
But the sign that actually settles the case is a second projection. The axillary view looks down the joint from above and shows the head sitting behind the glenoid directly; the scapular Y view shows the head displaced posterior to the centre of the Y. If pain prevents the axillary position, a modified axillary (Velpeau) view or CT answers the question. The rule is short and repeatedly ignored: never clear a shoulder on one projection.
What it changes
Recognition changes everything downstream, because a posterior dislocation left in place keeps destroying the joint: the impaction fracture deepens with time, the head can lock permanently, and delayed diagnosis converts a closed reduction into reconstructive surgery. Recognised acutely, the pathway is analgesia, proper imaging, and reduction by an experienced operator — with the specific caveat that a large reverse Hill-Sachs defect or an associated fracture changes the reduction plan and warrants orthopaedic involvement first. The bilateral case deserves a sentence of its own: after a seizure or electrocution both shoulders can dislocate posteriorly, and the second, quieter shoulder is the one that gets missed. Examine both.
What a negative does not exclude
A "normal" AP film does not exclude posterior dislocation — that is the entire lesson of this case, and it generalises: a single view of any joint clears nothing. The exclusion requires orthogonal imaging of an examinable joint. And even a technically adequate, genuinely normal series does not exclude the injuries that share this mechanism — proximal humeral fracture, rotator cuff injury after first-time dislocation in older patients, and the glenoid rim fractures that accompany dislocations. A patient who cannot externally rotate the arm has a mechanical explanation until one is found; the film's job is to show it, and a film that fails to is an indication for more imaging, not reassurance.
The traps
- Trusting the AP because it was reported normal. The projection cannot show backward displacement; normality on it is weak evidence.
- Attributing post-ictal shoulder pain to muscular strain. After a seizure, a painful shoulder in fixed internal rotation has earned proper imaging every time.
- Missing the bilateral case. Symmetry hides pathology — two lightbulbs look "symmetrical and normal" to a tired eye.
- Calling the lightbulb on a normally rotated film. A deliberately internally rotated AP (positioning, habitus, pain) produces a round head without dislocation; the sign is read together with the clinical block to external rotation and confirmed on the orthogonal view.
- The chronic locked dislocation. Weeks-old cases present as "frozen shoulder" in clinic; the seizure history is the clue nobody asked about.
References
- Hawkins RJ, Neer CS, Pianta RM, Mendoza FX. Locked posterior dislocation of the shoulder. J Bone Joint Surg Am 1987.
- Cisternino SJ et al. The trough line: a radiographic sign of posterior shoulder dislocation. AJR 1978.
- Arndt JH, Sears AD. Posterior dislocation of the shoulder. AJR 1965 — rim sign.
- Rowe CR, Zarins B. Chronic unreduced dislocations of the shoulder. J Bone Joint Surg Am 1982.
- BMJ Learning / RCEM learning material on the frequently missed posterior dislocation — two-view rule.
3 questions to test yourself on this dose are in the app.