Cricoid Pressure —
EMOD · Safe to Stop 24 of 30
Open in the appFree, works on your phone and offline, with every tool alongside.
WE ALWAYS: Press during every rapid sequence induction EVIDENCE: No demonstrated benefit, and it worsens the view A manoeuvre that makes intubation harder needs to earn its place.
1 · The case
A 64-year-old with a gastrointestinal bleed needs the airway secured. The team assembles, the drugs are drawn, and the newest nurse in the room is asked to apply cricoid pressure — because she is the person nearest the head who is not doing anything else. Nobody has told her how much force, nobody has shown her the landmark, and there is no way for anyone to know whether she is pressing on the cricoid, the thyroid cartilage, or the larynx as a whole. The view at laryngoscopy is a grade 3. Two attempts later, someone finally says "release cricoid", the view improves, and the tube passes. That release was never part of the plan; it was an improvisation at the second failure.
2 · The argument
The manoeuvre rests on a foundation far thinner than its adoption suggests. Sellick's 1961 description in the Lancet was a small case series with a physiological rationale — occlude the oesophagus against the vertebral body and prevent passive regurgitation during induction. It was never a trial, it long predated modern anaesthetic technique, and it entered universal practice on the strength of plausibility. For six decades it has been taught as mandatory in rapid sequence induction by people who, if asked, could not name the evidence.
When it was finally tested, the benefit did not appear. The IRIS trial — a large, multicentre, randomised, double-blind non-inferiority trial in French operating theatres, published in JAMA Surgery — compared cricoid pressure with a sham manoeuvre in patients undergoing rapid sequence induction. The trial did not demonstrate that cricoid pressure prevented aspiration; non-inferiority of the sham was not formally established on the trial's own strict statistical criteria, but the incidence of pulmonary aspiration was low in both groups and no protective effect was shown. Intubation time was longer with cricoid pressure, and the laryngoscopic view was more often difficult.
The mechanistic objections are also substantial. Imaging studies have shown that the oesophagus is frequently lateral to the cricoid rather than directly behind it, so the compression may not do what the model assumes. Cricoid pressure has been shown to worsen the laryngoscopic view, to impede bag-mask ventilation, to hinder placement of supraglottic airway devices, and to reduce lower oesophageal sphincter tone. Each of these degrades performance at exactly the moment when performance matters most.
And the practical failure is the one that should trouble us most. The force is not standardised in practice, the person applying it is very often the least experienced in the room, they have usually had no training in the required force or landmark, and there is no feedback loop telling anyone whether it is being done correctly. An intervention that cannot be measured cannot be audited, and cannot honestly be said to be practised consistently at all. We are not, in most departments, applying "cricoid pressure"; we are applying an unmeasured force to an approximate location and recording that a protocol step was completed.
What this page asks for is narrower than abolition. Know why you are doing it. Know that the person applying it needs to be shown the landmark and the force. Know that pressure applied to the thyroid cartilage for laryngeal manipulation is a different manoeuvre with a different purpose, and do not confuse them. And, above all, make release an explicit, rehearsed, spoken step in your failed-view sequence — not an improvisation at the second attempt.
3 · Local protocol governs
This item touches departmental protocol directly, and the page defers to it. Many departments' rapid sequence induction checklists specify cricoid pressure. Where that is your protocol, follow it. Mid-intubation is categorically not the moment to relitigate departmental policy — a team that is not operating from a shared plan at the moment of induction is less safe than one following a protocol with imperfect evidence.
The place to change it is governance: the airway lead, the joint ED-anaesthesia airway group, the checklist review. Bring the IRIS trial and the difficult airway guidance, and bring the more actionable proposal too, which most departments will accept even if they keep the manoeuvre — that release of cricoid pressure be written into the failed-view algorithm as an explicit early step, and that whoever applies it be trained rather than merely nearest.
4 · The evidence
Sellick BA, Lancet 1961. The original description of cricoid pressure to control regurgitation during induction — a case series with a physiological rationale, not a controlled trial, and the entire original basis for near-universal adoption.
Birenbaum A, et al. (IRIS trial), JAMA Surgery 2019. Multicentre randomised double-blind non-inferiority trial of cricoid pressure versus sham during rapid sequence induction: no protective effect against pulmonary aspiration demonstrated, with longer intubation times and more difficult laryngoscopic views in the cricoid group; the trial's formal non-inferiority criterion for the sham was not met, which is why this evidence is best described as failing to show benefit rather than as proving the manoeuvre useless.
Difficult Airway Society guidelines for management of unanticipated difficult intubation in adults (Frerk et al., British Journal of Anaesthesia 2015). Addresses cricoid pressure within rapid sequence induction and states that it should be reduced or removed if it is impeding laryngoscopy, ventilation or supraglottic airway placement.
Anatomical and imaging studies of the oesophagus relative to the cricoid, demonstrating frequent lateral displacement of the oesophagus and questioning the mechanism the manoeuvre assumes.
5 · Still justified when
- Local protocol requires it. Protocol governs at the bedside; change belongs at governance. This is the primary and honest answer for most readers of this page.
- Where a department has retained it deliberately after reviewing the evidence — a defensible position, since the trial evidence fails to demonstrate benefit rather than demonstrating harm-in-net for every patient — provided the people applying it are trained in the landmark and force.
- In high-aspiration-risk inductions where the team has agreed in advance that it will be used, with the release plan stated aloud as part of the pre-intubation briefing.
And in every case, three conditions that should be non-negotiable regardless of which side of the argument your department is on:
- The person applying it has been shown the landmark and the force, and is not simply the nearest available pair of hands.
- Release is an explicit early step in the failed-view sequence, spoken aloud so the whole team knows it has happened.
- It is distinguished clearly from external laryngeal manipulation or BURP, which is applied to the thyroid cartilage to improve the view and is a different manoeuvre for a different purpose.
7 · References
- Sellick BA. Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia. Lancet 1961.
- Birenbaum A, et al. Effect of cricoid pressure compared with a sham procedure in the rapid sequence induction of anesthesia: the IRIS randomized clinical trial. JAMA Surgery 2019.
- Frerk C, et al. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. British Journal of Anaesthesia 2015.
- Imaging studies of oesophageal position relative to the cricoid cartilage.
3 questions to test yourself on this dose are in the app.